77
SAMSUNG ELECTRONICS
9-2-5 Outdoor Cond temperature sensor error
Indoor display
7 SEG DISPLAY
DESCRIPTION
C231
Outdoor Cond temperature sensor error
Outdoor display
Outdoor Cond temperature sensor error
: LAMP ON
: LAMP OFF
: LAMP BLINK
1. Checklist :
1) Is the sensor connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull-up correct?
2. Troubleshooting procedure
Isthe sensor connector("A")
connected correctly in accordance
with a color?
NO
YES
Reconnect the sensor connector.
Isthe sensorresistance value
"B" 10kohm±3%attheroomtemperature
of 25
NO
YES
Sensor Replace
Sensor resistance value 20 - 12.09kohm
30 -8.31kohm
35 - 6.94kohm
40 - 5.83kohm
Connectthe sensorto PBA connector
supply power and measure the voltage of "B"
intheconnector
Below 0.5Vdc or Over 4.5Vdc?
YES
NO
Exchange the Outdoor PBA
YES
Exchange the Outdoor PBA
Micom error or connectorcheck
Model
"A"
"B"
All
CN251
CN251 #5-#6
Summary of Contents for AR07TXCAAWKNEU
Page 49: ...49 SAMSUNG ELECTRONICS 5 2 ASSY KIT CODE DB92 04839Q ...
Page 50: ...50 SAMSUNG ELECTRONICS 5 3 ASSY KIT CODE DB92 04839Q ...
Page 59: ...59 SAMSUNG ELECTRONICS 6 Wiring Diagram 6 1 Indoor Unit CODE DB68 08680A 01 ...
Page 61: ...61 SAMSUNG ELECTRONICS 7 PCB Diagram 7 1 Indoor Main PCB DB92 04839A ...
Page 62: ...62 SAMSUNG ELECTRONICS 7 2 Outdoor PCB DB92 04837A ...
Page 63: ...63 SAMSUNG ELECTRONICS ...
Page 67: ...67 SAMSUNG ELECTRONICS 8 5 DISPLAY PCB DB92 04833B ...