Product Specifications
Samsung Electronics
9
2-2 Model names of Indoor/Outdoor Unit
2-2-1 Outdoor unit combination
■ AM***BXVG* series
Model name for
combination
Numberof individual
outdoor units
Nominal Capacity
Rated Capacity
Total cooling capacity of the
connected indoorunits
Maximum number of con-
nectable indoorunits
Combined outdoorunits
AM***BXVG**
Cooling
(Btu/h)
Heating
(Btu/h)
Cooling
(Btu/h)
Heating
(Btu/h)
Minimum
(Btu/h)
Maximum
(Btu/h)
72 (6Ton)
96 (8Ton)
120 (10Ton) 144 (12Ton) 168 (14Ton) 192 (16Ton) 216 (18Ton) 240 (20Ton)
AM072BXVG**
1
72000
81000
69000
77000
36000
93600
12
1
AM096BXVG**
1
96000
108000
92000
103000
48000
124800
16
1
AM120BXVG**
1
120000
135000
114000
129000
60000
156000
20
1
AM144BXVG**
1
144000
162000
138000
154000
72000
187200
25
1
AM168BXVG**
1
168000
189000
160000
180000
84000
218400
29
1
AM192BXVG**
1
192000
216000
184000
206000
96000
249600
33
1
AM216BXVG**
1
216000
243000
206000
232000
108000
280800
37
1
AM240BXVG**
1
240000
270000
228000
258000
120000
312000
41
1
AM264BXVG**
2
264000
297000
252000
282000
132000
343200
45
1
1
AM288BXVG**
2
288000
324000
274000
308000
144000
374400
49
1
1
AM312BXVG**
2
312000
351000
298000
334000
156000
405600
54
1
1
AM336BXVG**
2
336000
378000
320000
360000
168000
436800
58
1
1
AM360BXVG**
2
360000
405000
342000
386000
180000
468000
62
1
1
AM384BXVG**
2
384000
432000
366000
412000
192000
499200
64
2
AM408BXVG**
2
408000
459000
388000
438000
204000
530400
64
1
1
AM432BXVG**
2
432000
486000
412000
462000
216000
561600
64
2
AM456BXVG**
3
456000
513000
436000
488000
228000
592800
64
1
1
1
AM480BXVG**
3
480000
540000
458000
514000
240000
624000
64
1
1
1
▶ Make sure to use an indoor unit that is compatible with DVM S2.
▶ Indoor units can be connected within the range indicated in following table.
▶ If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating capacity of the indoor unit may decrease.
▶ Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity. 0.5 × Σ( Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ( Outdoor unit capacity)
※ You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is set to 64 since outdoor unit only support up to 64 communication address. Indoor unit address can be assigned from 0~63. If the indoor unit address was assigned from 64~79, E201 error will occur.
※ Maximum 32 Wall-mount type indoor units with EEV (AM∗∗∗∗NQD∗∗∗, AM∗∗∗NVD∗∗∗) can be connected.