129
12. Capacity Table
Combination
(Capacity Index)
Combination
(Total)
Combination
(%)
Outdoor
Temperature
(℃,DB)
Indoor Temperature(℃, DB)
14
16
18
20
21
22
24
TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW)
2000 3500
5500
138%
-15
2.40
0.74
2.33
0.75
2.26
0.76
2.23
0.76
2.20
0.77
2.15
0.78
2.11
0.78
-10
2.88
0.78
2.80
0.79
2.73
0.80
2.70
0.80
2.67
0.81
2.61
0.82
2.57
0.82
-5
3.36
0.82
3.27
0.83
3.20
0.84
3.16
0.84
3.13
0.85
3.07
0.86
3.02
0.87
0
3.83
0.85
3.75
0.87
3.66
0.88
3.63
0.88
3.59
0.89
3.53
0.90
3.48
0.91
2
4.02
0.87
3.93
0.88
3.85
0.89
3.81
0.90
3.78
0.91
3.71
0.91
3.66
0.92
7
4.41
0.90
4.31
0.91
4.23
0.93
4.20
0.93
4.15
0.94
4.08
0.95
4.02
0.96
10
4.79
0.93
4.69
0.94
4.60
0.96
4.56
0.96
4.52
0.97
4.45
0.98
4.39
0.99
15
5.27
0.97
5.17
0.98
5.08
1.00
5.03
1.00
4.99
1.01
4.91
1.02
4.85
1.03
2500 2500
5000
125%
-15
2.40
0.75
2.33
0.76
2.26
0.77
2.23
0.77
2.20
0.78
2.15
0.78
2.11
0.79
-10
2.88
0.79
2.80
0.80
2.73
0.81
2.70
0.81
2.67
0.82
2.61
0.83
2.57
0.83
-5
3.36
0.83
3.27
0.84
3.20
0.85
3.16
0.85
3.13
0.86
3.07
0.87
3.02
0.87
0
3.83
0.86
3.75
0.88
3.66
0.89
3.63
0.89
3.59
0.90
3.53
0.91
3.48
0.92
2
4.02
0.88
3.93
0.89
3.85
0.90
3.81
0.91
3.78
0.91
3.71
0.92
3.66
0.93
7
4.41
0.91
4.31
0.92
4.23
0.94
4.20
0.94
4.15
0.95
4.08
0.96
4.02
0.97
10
4.79
0.94
4.69
0.95
4.60
0.97
4.56
0.97
4.52
0.98
4.45
0.99
4.39
1.00
15
5.27
0.98
5.17
0.99
5.08
1.01
5.03
1.01
4.99
1.02
4.91
1.03
4.85
1.04
2500 3500
6000
150%
-15
2.40
0.76
2.33
0.77
2.26
0.78
2.23
0.78
2.20
0.79
2.15
0.79
2.11
0.80
-10
2.88
0.79
2.80
0.81
2.73
0.82
2.70
0.82
2.67
0.83
2.61
0.83
2.57
0.84
-5
3.36
0.83
3.27
0.85
3.20
0.86
3.16
0.86
3.13
0.87
3.07
0.88
3.02
0.88
0
3.83
0.87
3.75
0.89
3.66
0.90
3.63
0.90
3.59
0.91
3.53
0.92
3.48
0.93
2
4.02
0.89
3.93
0.90
3.85
0.91
3.81
0.92
3.78
0.92
3.71
0.93
3.66
0.94
7
4.41
0.92
4.31
0.93
4.23
0.95
4.20
0.95
4.15
0.96
4.08
0.97
4.02
0.98
10
4.79
0.95
4.69
0.96
4.60
0.98
4.56
0.98
4.52
0.99
4.45
1.00
4.39
1.01
15
5.27
0.99
5.17
1.00
5.08
1.02
5.03
1.02
4.99
1.03
4.91
1.04
4.85
1.05
NOTE
•
The performance table shows the average value of each conditions.
•
The above is the value for connecting with the following indoor units.
- 2000, 2500, 3500W class : AR07TXFCAWKNEU, AR09TXFCAWKNEU, AR12TXFCAWKNEU
•
The total ability of connected a indoor unit is up to 6.0kW
•
It is impossible to connect the indoor unit for one room only.
•
This data is reference data for temperature capacity trend.