48
4. Combination Table
4. Combination Table
4-3 AJ052TXJ3KG/EU
COOLING
Outdoor unit
A
B
C
Cooling Capacity
Capacity
Power
Consumption
Current
Effic. NOM.
Cooling.
At 35℃/27℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SEER
Qce
W
W
W
A
A
B
C
MIN STD MAX MIN STD MAX MIN STD MAX
EER
Class
kWh
AJ052TXJ3KG
2 Unit
7
7
2000 2000
1100 4000 4800 320 1020 1630
2
4.5
7.5
3.92
A++
8.08
173
7
9
2040 2560
1100 4600 5520 320 1170 1850
2
5.2
8.5
3.93
A++
7.73
208
7
12
1820 3180
1100 5000 6290 320 1260 2000
2
5.6
9.2
3.97
A++
8.15
215
7
18
1490 3710
1200 5200 6600 320 1300 2040
2
5.7
9.3
4.00
A++
7.85
232
9
9
2500 2500
1100 5000 5800 320 1160 1980
2
5.1
9.1
4.30
A+++
8.51 206
9
12
2080 2920
1100 5000 6400 320 1250 2020
2
5.5
9.2
4.00
A++
8.16
214
9
18
1730 3470
1200 5200 6800 320 1300 2070
2
5.7
9.5
4.00
A++
7.85
232
12
12
2600 2600
1100 5200 6560 320 1300 2040
2
5.7
9.3
4.00
A++
8.16
214
3 Unit
7
7
7
1730 1730 1740 1450 5200 6380 330 1280 2020
2
5.7
9.2
4.06
A++
7.68
237
7
7
9
1600 1600 2000 1450 5200 6490 330 1290 2040
2
5.7
9.3
4.03
A++
7.67
237
7
7
12
1390 1390 2420 1450 5200 6800 330 1270 2070
2
5.6
9.5
4.09
A++
7.69
237
7
9
9
1480 1860 1860 1450 5200 6600 330 1260 2040
2
5.6
9.3
4.13
A++
7.7
236
7
9
12
1300 1630 2270 1450 5200 6800 330 1270 2070
2
5.6
9.5
4.11
A++
7.69
237
9
9
9
1730 1730 1740 1450 5200 6800 330 1250 2070
2
5.5
9.5
4.16
A++
7.7
236
9
9
12
1530 1530 2140 1450 5200 6800 330 1250 2070
2
5.5
9.5
4.16
A++
8.08 225
HEATING
Outdoor unit
A
B
C
Heating
Capacity
Capacity
Power
Consumption
Current
Effic. NOM.
Heating.
At 7℃/20℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SCOP
P
design Qhe
W
W
W
A
A
B
C
MIN STD MAX MIN STD MAX MIN STD MAX
COP
Class
kW
kWh
AJ052TXJ3KG
2 Unit
7
7
2200 2200
950 4400 5060 280 1150 1510 1.7
5.4
6.9
3.83
A+
4.40
3.05
970
7
9
2040 3060
950 5100 5870 280 1320 1830 1.7
6.1
8.4
3.86
A+
4.35
4.21
1352
7
12
1990 3610
950 5600 6440 280 1450 1860 1.7
6.7
8.5
3.86
A+
4.34
4.60 1484
7
18
1610 4390
950 6000 6900 280 1570 1860 1.7
7.2
8.5
3.82
A+
4.27
4.28 1401
9
9
2900 2900
950 5800 6300 280 1510 1910 1.7
6.9
8.7
3.84
A++
4.60
4.60 1400
9
12
2620 3180
950 5800 6300 280 1510 1910 1.7
6.9
8.7
3.84
A+
4.34
4.60 1484
9
18
2240 4060
950 6300 7300 280 1640 1830 1.7
7.5
8.4
3.84
A+
4.27
4.28 1401
12
12
2950 2950
950 5900 6880 280 1530 1860 1.7
7.0
8.5
3.86
A+
4.34
4.60 1484
3 Unit
7
7
7
1930 1930 1940 1000 5800 6760 280 1500 1840 1.7
6.9
8.4
3.87
A+
4.30
4.60 1497
7
7
9
1690 1690 2520 1000 5900 6840 280 1550 1840 1.7
7.1
8.4
3.81
A+
4.30
4.60 1497
7
7
12 1650 1650 3000 1000 6300 7300 280 1560 1830 1.7
7.1
8.4
4.04
A+
4.30
4.60 1497
7
9
9
1500 2250 2250 1000 6000 6920 280 1500 1840 1.7
6.9
8.4
4.00
A+
4.30
4.60 1497
7
9
12 1460 2190 2650 1000 6300 7300 280 1530 1830 1.7
7.0
8.4
4.12
A+
4.30
4.60 1497
9
9
9
2100 2100 2100 1000 6300 7300 280 1320 1830 1.7
6.1
8.4
4.77
A+
4.30
4.60 1497
9
9
12 1850 1850 2600 1000 6300 7300 280 1320 1830 1.7
6.1
8.4
4.77
A+
4.30
4.60 1497
NOTE
1
EER and COP declared only for the purpose of tax deductions in force at the time of the creation of this catalog.
2
The above is the value for connecting with the following indoor units.
- Wind Free(PRM) : AR07TXCAAWK, AR09TXCAAWK, AR12TXCAAWK
3
You can not connect a single unit.
4
Power consumption include indoor unit power.