80
7. Electrical Wiring Diagram
7-1 Outdoor unit
3
AJ100TXJ5KG/EU
ASSY PCB INVERTER
Printed circuit
board(Inverter PBA)
BASE HEATER
Heating Wire
PIPE OUT TH - A
Thermistor(A Pipe
Out Temp. - 10kohm)
ASSY PCB SUB-EMI
Printed circuit
board(EMI PBA)
OUT-TH
Thermistor(Ambient Temp.
- 10kohm)
PIPE OUT TH - B
Thermistor(B Pipe
Out Temp. - 10kohm)
ASSY PCB MAIN-OUT
Printed circuit
board(Main PBA)
DIS-TH
Thermistor(Discharge
Temp. - 200kohm)
PIPE OUT TH - C
Thermistor(C Pipe Out
Temp. - 10kohm)
FH152(250V/T1.6A)
Fuse(Inverter PBA)
COND-TH
Thermistor(Condensor
Temp. - 10kohm)
PIPE OUT TH - D
Thermistor(D Pipe
Out Temp. - 10kohm)
FH901(250V/T3.15A)
Fuse(Inverter PBA)
OLP-TH
Thermistor(Compressor Top
Temp. - 200kohm)
PIPE OUT TH - E
Thermistor(E Pipe Out
Temp. - 10kohm)
F101(250V/T40A)
Fuse(EMI PBA)
PIPE IN TH - A
Thermistor(A Pipe In Temp.
- 10kohm)
EEV - A
Electronic Expansion
Valve A
F100(250V/T2.5A)
Fuse(Main PBA)
PIPE IN TH - B
Thermistor(B Pipe In Temp.
- 10kohm)
EEV - B
Electronic Expansion
Valve B
F101(250V/T2.5A)
Fuse(Main PBA)
PIPE IN TH - C
Thermistor(C Pipe In Temp.
- 10kohm)
EEV - C
Electronic Expansion
Valve C
COMPRESSOR
Motor(Compressor)
PIPE IN TH - D
Thermistor(D Pipe In Temp.
- 10kohm)
EEV - D
Electronic Expansion
Valve D
M-BLDC
Motor(FAN)
PIPE IN TH - E
Thermistor(E Pipe In Temp.
- 10kohm)
EEV - E
Electronic Expansion
Valve E
4WAY VALVE
Solenoid Valve(4Way)
NOTE
•
This wiring diagram applies only to the outdoor unit.
•
Colors BLK : black, BRN : brown, SKY-BLU : sky-blue, GRN/YEL : green/yellow, RED : red, YEL : yellow,
ORG : orange, BLU : blue, WHT: white
•
For connection wiring indoor-outdoor transmission 3(C), refer to the installation manual
•
Protective earth(screw)