12. Capacity Table
Combination
(Capacity Index)
Combination
(Total)
Combination
(%)
Outdoor
Temperature
(℃,DB)
Indoor Temperature(℃, WB)
14
16
18
19
20
22
24
TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW)
2500 2500 3500
8500
163%
10
5.85
0.88
6.08
0.90
6.31
0.91
6.43
0.92
6.55
0.93
6.79
0.95
7.03
0.97
12
5.75
0.90
5.98
0.92
6.21
0.94
6.33
0.95
6.45
0.96
6.69
0.98
6.93
0.99
14
5.64
0.92
5.87
0.94
6.11
0.96
6.23
0.97
6.35
0.98
6.59
1.00
6.83
1.02
16
5.54
0.95
5.77
0.97
6.01
0.99
6.13
1.00
6.25
1.01
6.49
1.03
6.73
1.04
18
5.44
0.97
5.67
0.99
5.91
1.01
6.03
1.02
6.15
1.03
6.39
1.05
6.63
1.07
20
5.34
1.00
5.57
1.02
5.81
1.04
5.93
1.05
6.05
1.06
6.29
1.08
6.54
1.10
21
5.29
1.01
5.52
1.03
5.76
1.05
5.88
1.06
6.00
1.07
6.24
1.09
6.49
1.11
23
5.19
1.04
5.42
1.06
5.66
1.08
5.78
1.09
5.90
1.10
6.14
1.12
6.39
1.14
25
5.09
1.06
5.32
1.08
5.56
1.10
5.68
1.11
5.80
1.12
6.04
1.14
6.29
1.16
27
4.99
1.09
5.23
1.11
5.46
1.13
5.58
1.14
5.70
1.15
5.95
1.17
6.19
1.19
29
4.89
1.12
5.13
1.14
5.36
1.16
5.48
1.17
5.60
1.18
5.85
1.20
6.10
1.22
31
4.79
1.15
5.03
1.17
5.27
1.19
5.39
1.20
5.51
1.21
5.75
1.23
6.00
1.25
33
4.69
1.17
4.93
1.19
5.17
1.21
5.29
1.22
5.41
1.23
5.65
1.25
5.90
1.27
35
4.60
1.20
4.83
1.22
5.07
1.24
5.20
1.25
5.31
1.26
5.56
1.28
5.81
1.30
37
4.50
1.23
4.73
1.25
4.97
1.27
5.09
1.28
5.22
1.29
5.46
1.31
5.71
1.33
39
4.40
1.26
4.64
1.28
4.88
1.30
5.00
1.31
5.12
1.32
5.36
1.34
5.61
1.36
42
4.25
1.31
4.49
1.33
4.73
1.35
4.85
1.36
4.97
1.37
5.22
1.39
5.47
1.41
44
4.16
1.34
4.39
1.36
4.63
1.38
4.76
1.39
4.88
1.40
5.13
1.42
5.38
1.44
46
4.06
1.37
4.30
1.39
4.54
1.41
4.66
1.42
4.78
1.43
5.03
1.45
5.28
1.47
NOTE
•
Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).
•
Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).
•
The above is the value for connecting with the following indoor units.
- 2000, 2500, 3500, 5000W class : AR07TXFCAWKNEU, AR09TXFCAWKNEU, AR12TXFCAWKNEU, AR18TXEAAWKNEU
•
Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 5m / - Level difference : 0m
•
The total ability of connected a indoor unit is up to 7.5kW
•
It is impossible to connect the indoor unit for one room only.
•
This data is reference data for temperature capacity trend.