12. Capacity Table
Combination
(Capacity Index)
Combination
(Total)
Combination
(%)
Outdoor
Temperature
(℃,DB)
Indoor Temperature(℃, DB)
14
16
18
20
21
22
24
TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW) TC(kW) PI(kW)
2500 2500 3500
8500
125%
-15
4.58
1.52
4.44
1.54
4.31
1.56
4.25
1.57
4.20
1.58
4.10
1.59
4.02
1.61
-10
5.49
1.60
5.33
1.62
5.20
1.64
5.14
1.65
5.08
1.66
4.97
1.68
4.89
1.69
-5
6.39
1.68
6.23
1.70
6.09
1.72
6.02
1.73
5.96
1.74
5.85
1.76
5.75
1.78
0
7.30
1.76
7.13
1.78
6.98
1.80
6.91
1.82
6.84
1.83
6.72
1.85
6.62
1.86
2
7.67
1.79
7.49
1.81
7.34
1.84
7.27
1.85
7.20
1.86
7.07
1.88
6.97
1.90
7
8.40
1.85
8.22
1.88
8.05
1.90
8.00
1.91
7.91
1.92
7.78
1.94
7.66
1.96
10
9.12
1.91
8.94
1.94
8.77
1.96
8.69
1.98
8.62
1.99
8.48
2.01
8.36
2.03
15
10.04
1.99
9.84
2.02
9.67
2.04
9.58
2.06
9.51
2.07
9.36
2.09
9.23
2.11
2500 2500 5000
10000
147%
-15
4.58
1.55
4.44
1.57
4.31
1.59
4.25
1.60
4.20
1.61
4.10
1.63
4.02
1.64
-10
5.49
1.63
5.33
1.66
5.20
1.68
5.14
1.69
5.08
1.70
4.97
1.71
4.89
1.73
-5
6.39
1.71
6.23
1.74
6.09
1.76
6.02
1.77
5.96
1.78
5.85
1.80
5.75
1.81
0
7.30
1.79
7.13
1.82
6.98
1.84
6.91
1.85
6.84
1.86
6.72
1.88
6.62
1.90
2
7.67
1.82
7.49
1.85
7.34
1.88
7.27
1.89
7.20
1.90
7.07
1.92
6.97
1.94
7
8.40
1.89
8.22
1.92
8.05
1.94
8.00
1.95
7.91
1.96
7.78
1.99
7.66
2.00
10
9.12
1.95
8.94
1.98
8.77
2.01
8.69
2.02
8.62
2.03
8.48
2.05
8.36
2.07
15
10.04 2.03
9.84
2.06
9.67
2.09
9.58
2.10
9.51
2.11
9.36
2.14
9.23
2.16
2500 3500 3500
9500
140%
-15
4.58
1.53
4.44
1.56
4.31
1.58
4.25
1.59
4.20
1.60
4.10
1.61
4.02
1.62
-10
5.49
1.61
5.33
1.64
5.20
1.66
5.14
1.67
5.08
1.68
4.97
1.70
4.89
1.71
-5
6.39
1.69
6.23
1.72
6.09
1.74
6.02
1.75
5.96
1.76
5.85
1.78
5.75
1.80
0
7.30
1.77
7.13
1.80
6.98
1.82
6.91
1.83
6.84
1.85
6.72
1.86
6.62
1.88
2
7.67
1.80
7.49
1.83
7.34
1.86
7.27
1.87
7.20
1.88
7.07
1.90
6.97
1.92
7
8.40
1.87
8.22
1.90
8.05
1.92
8.00
1.93
7.91
1.94
7.78
1.96
7.66
1.98
10
9.12
1.93
8.94
1.96
8.77
1.99
8.69
2.00
8.62
2.01
8.48
2.03
8.36
2.05
15
10.04 2.01
9.84
2.04
9.67
2.07
9.58
2.08
9.51
2.09
9.36
2.11
9.23
2.13
2500 3500 5000
11000
162%
-15
4.58
1.57
4.44
1.60
4.31
1.62
4.25
1.63
4.20
1.64
4.10
1.65
4.02
1.67
-10
5.49
1.66
5.33
1.68
5.20
1.70
5.14
1.71
5.08
1.72
4.97
1.74
4.89
1.75
-5
6.39
1.74
6.23
1.76
6.09
1.79
6.02
1.80
5.96
1.81
5.85
1.83
5.75
1.84
0
7.30
1.82
7.13
1.85
6.98
1.87
6.91
1.88
6.84
1.89
6.72
1.91
6.62
1.93
2
7.67
1.85
7.49
1.88
7.34
1.90
7.27
1.92
7.20
1.93
7.07
1.95
6.97
1.96
7
8.40
1.92
8.22
1.94
8.05
1.97
8.00
1.98
7.91
1.99
7.78
2.02
7.66
2.03
10
9.12
1.98
8.94
2.01
8.77
2.04
8.69
2.05
8.62
2.06
8.48
2.08
8.36
2.10
15
10.04 2.06
9.84
2.09
9.67
2.12
9.58
2.13
9.51
2.14
9.36
2.17
9.23
2.19
3500 3500 3500
10500
154%
-15
4.58
1.52
4.44
1.54
4.31
1.56
4.25
1.57
4.20
1.58
4.10
1.59
4.02
1.61
-10
5.49
1.60
5.33
1.62
5.20
1.64
5.14
1.65
5.08
1.66
4.97
1.68
4.89
1.69
-5
6.39
1.68
6.23
1.70
6.09
1.72
6.02
1.73
5.96
1.74
5.85
1.76
5.75
1.78
0
7.30
1.76
7.13
1.78
6.98
1.80
6.91
1.82
6.84
1.83
6.72
1.85
6.62
1.86
2
7.67
1.79
7.49
1.81
7.34
1.84
7.27
1.85
7.20
1.86
7.07
1.88
6.97
1.90
7
8.40
1.85
8.22
1.88
8.05
1.90
8.00
1.91
7.91
1.92
7.78
1.94
7.66
1.96
10
9.12
1.91
8.94
1.94
8.77
1.96
8.69
1.98
8.62
1.99
8.48
2.01
8.36
2.03
15
10.04
1.99
9.84
2.02
9.67
2.04
9.58
2.06
9.51
2.07
9.36
2.09
9.23
2.11
NOTE
•
Cooling capacity is based on 27°CDB / 19°CWB (indoor temperature), 35°CDB (outdoor temperature).
•
Heating capacity is based on 20°CDB (indoor temperature), 7°CDB/6°CWB (outdoor temperature).
•
The above is the value for connecting with the following indoor units.
- 2000, 2500, 3500, 5000W class : AR07TXFCAWKNEU, AR09TXFCAWKNEU, AR12TXFCAWKNEU, AR18TXEAAWKNEU
•
Capacities are based on the following conditions:
- Corresponding refrigerant piping length : 5m / - Level difference : 0m
•
The total ability of connected a indoor unit is up to 7.5kW
•
It is impossible to connect the indoor unit for one room only.
•
This data is reference data for temperature capacity trend.