Before running the system
Self test mode
①
⑧
②
③
④
⑤
⑥
⑦
(3sec) Enter Self Test
Mode
Function OFF / (3sec)
Quit Self Test Mode
①
Water Pump
②
Back up Heater 1
st
state
③
Back up Heater 2
st
state
④
Booster Heater
⑤
Back up Boiler
⑥
DHW Valve
⑦
Zone #1 Valve
⑧
Zone #2 Valve
Sho
Z¿
ve temp
sensor
values in order
J
J
J
J
Not available
Thermostat (Heating)
No
1 / No
2
Thermostat (Cooling)
No
1 / No.2
Setting option switches and function of keys
1. Self test mode
- Self Test Mode is implemented ignoring errors .
- It can be implemented without OUTDOOR UNIT installation .
- Buttons have new functions as shown in the upper table under the Self Test Mode
2. Enter and quit Self test mode
Ź
To enter Self test mode
- Set DIP #5 (wired remote controller) “ON” and reset power.
- Press both “Set” and “Test” buttons over 3 sec .
- ‘TEST’ icon and sign pop up.
Ź
To quit the self test mode
- Press “Cancel “ button over 3 sec .
3. How to use
- ‘Not available’ icon pops up when the buttons not shown in the upper table are pressed.
- All the functions’ default states are “OFF”
- Pressing the button (#1~#8) makes its function “ON” and Cancel button makes all the functions “OFF”
- Back up Heater 1(button#2) and 2(button#3) are not available when the Water Pump (button #1) is not “ON”
- Every time you press the View button, it shows temperature sensor values in order . PHE water inlet
ĺ
PHE water outlet
ĺ
Backup Heater outlet
ĺ
Water Tank
ĺ
Room. It goes back to the previous state when there is no View button input
for 5 sec.
- ‘HEAT’ or ‘COOL’ sign and thermostat icon pop up instead of ‘TEST’ sign when the thermostat is connected .
Summary of Contents for AEN160YDEHA
Page 1: ......
Page 11: ...E 11 ENGLISH Dimensional drawing 131 7 78 5 103 7 104 0 125 0 490 22 0 39 2 850 0 510 0 314 6 ...
Page 22: ...E 22 Wiring diagram AEN160YDGHA Wiring work Continued ...
Page 23: ...E 23 ENGLISH Wiring diagram AEN160YDEHA AEN080YDEHA ...
Page 38: ...E 38 DHW tank Continued Accessories Leg 3 Anode bar 1 Conduit 1 ...
Page 48: ......