Installing the unit
Installation of the indoor unit
The indoor unit should be installed indoors and meet the following conditions.
X
Installation site should be sheltered from frost.
X
In area with suitable space for servicing.
X
A place with adequate ventilation.
X
Where there is no risk of leakage of flammable gases.
X
There is a provision for condensate drain and pressure relief valve blow-off.
X
The wall for installation is a flat, vertical and non-combustible wall, capable of supporting the operation
weight of the unit.
Installation space
X
Ensure to leave the appropriate space as indicated in the drawing.
X
Installation site should be secured with adequate ventilation so that the components of hydro unit will
not be damaged from overheating.
X
Before installing the indoor unit, fix the pattern sheet on the wall.
This sheet has a function to take correct position for the wall mounting bracket and screws.
300
500
200
≥1200
≥350
(Unit :mm)
<Pattern Sheet>