E-
43
ENGLISH
Wiring diagram
Make sure of a earthing.
X
Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire.
If earthing is incomplete, electric shock or fire may occur.
X
Turn on the DHW tank and hydro unit after completing electric wiring works.
X
Do not disassemble the wirings out of the unit while the unit is operating.
X
Circuit breaker shall be installed for safety and maintenance .
1
40.4
66T
DATE CODE
CAL LOT NO.
59T 4117
ø5.56
2 HOLES
59T
4
2
42.52
50.8
63.5
1
4
2
Outer casing
L
N
Electrical connections – Technical Data:
Electric element:
2.6 kW 230V 1 phase, 1 1/4” connection with O-ring seal
Adjustable: Electric output can be reduced by cutting one bridge on the element.
Thermostat: Adjustable 40~70°C(preset 60°C)
Safety cut-off: 91°C
Electric central:
Internally connected from factory. Splash proof IP21.
For installation in sanitary rooms special regulations apply.