background image

13

Monitor Mode Menus

Each screen and mode of operation also provides a number of menus.  Here is a description of the
various menu titles and options available when in Monitor Mode (the same menu items are
available in both the main Monitor screen and the Simple Monitor screen):

File - Options here allow you to create a New file; Open an existing one; Save the data in memory
to the current file; Save As (save the data in memory to a different file); Print the data in memory to
a printer; set various printer options (Printer Settings); and Exit the program.  For convenience,
recently opened .WSM files will also be listed in the File menu.  For more information, refer to the
WSM online Help.

Monitor - The functions in the Monitor menu (Play, Stop, Pause and Record) are identical to those in the
Transport Tools.  See page 12 in this manual (and the WSM online Help) for more information.

Timer - WSM provides a handy timer, useful for keeping track of how long you’ve
been recording or for calculating remaining transmitter battery life.  The timer
display is found in the bottom left-hand corner of the Monitor or Simple Monitor
screen, as shown on the left.  The options in the Timer menu are duplicated in the
timer display.  They allow you to Start the timer; Stop it; Reset it (to 00 hours,
00 minutes, 00 seconds); and Sync it, so that it only operates when in Monitor Play
or Record mode and stops during Monitoring is Stopped or Paused.  For more
information, refer to the WSM online Help.

Setup - Options in this menu allow you to call up various dialogs, including Channel Setup
(see page 10 in this manual for more information); Channel Plan (see page 9 in this manual
for more information); Scene Memory; or Program Title.  You can also switch to the Simple
Monitor screen from this menu.

Scenes are one of WSM’s most powerful
features.  The Scene Memory dialog
(shown at left) allows you to name and
store up to 20 scenes, each containing on-off status for
each connected receiver.  You can then activate any
scene in the Scene Memory on/off box in the Monitor
and Simple Monitor screen.  For more information,
refer to page 10 in this manual and to the WSM online
Help.

Display - Options in this menu allow you to turn the
Tool Bar and Status Bar on or off.  See page 12 in
this manual for more information.

Window - Standard Windows options in
this menu allow you to cascade, tile,
and arrange multiple windows in WSM.
This menu also allows you to switch
between WSM’s three main Modes of
operation: Monitor, Time Domain, and
Spectrum Analyze.

Help - The functions in the Help menu
(Search Topic and About WSM) are
identical to those in the Help Tools.
See page 12 in this manual for more
information.

Summary of Contents for WSM Wireless System Manager for Windows 95

Page 1: ...OWNERS MANUAL Wireless System Manager for Windows 95 Windows and Windows logo are registered trademarks of Microsoft Corp...

Page 2: ...lvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 Table of Contents Introduction 1 Hardware Interconnections 1 Software Installation 5 Launching Wireless Syst...

Page 3: ...Samson Wireless System Manager ever require servicing a Return Authorization number RA is necessary Without this number the unit will not be accepted Please call Samson at 1 800 372 6766 for a Return...

Page 4: ...connector cable to the joystick MIDI port of your computer s Sound Blaster 16 card and the other end to the PC connection on the IF6P If you need to remote your receivers 20 feet or more from the com...

Page 5: ...mini DIN cables to connect the Remote Out of the first receiver to the Remote In of the next one daisy chain fashion Then connect the Remote Out of the last UR6D or UR6DX receiver to the IF6P 1 In If...

Page 6: ...h on the side of both the IF6P and IF6R to 2 Alternatively as shown in the illustrations on the right you can use standard mic cable with XLR connectors again up to 200 meters in length Plug the male...

Page 7: ...perties dialog opens click on the Advanced tab Open the MIDI Devices and Instruments folder and select MIDI for External MIDI Port Click on Properties and the MIDI For External MIDI Port Properties di...

Page 8: ...lling the WSM application you need to first copy the font file named Lucon onto your hard disk This file must be placed inside the Fonts folder in the Windows folder as shown in the illustration on th...

Page 9: ...eated WSM file if one exists WSM files contain the current channel setup all recorded data and the contents of all Scene Memories It then scans all connected receivers to check that all parameters in...

Page 10: ...g Condition from the Settings menu or click on the Drawing Condition icon in the Tool Bar In the resulting dialog select the appropriate receiver tab s then check the data type s you wish to view RF L...

Page 11: ...up menu select the Channel Plan option The Channel Plan dialog shown at right will appear Begin by specifying the number of channels you want to have included in the plan To have WSM generate a channe...

Page 12: ...ied by WSM RX1 and RX2 Titles Audio Frequency RX AF on off Tone Squelch T SQ on off when off the box is colored yellow Mute on off when on the box is colored red Antenna A Attenuation ATT A Antenna B...

Page 13: ...RF Level meter for each receiver This meter shows the RF signal strength being received by the antenna currently in use and the legend beside it shows whether the A or B antenna is the current one In...

Page 14: ...see File Menu on page 13 of this manual Help Tools These icons are available in all screens The left icon displays the WSM version number and copyright information The right icon provides context sens...

Page 15: ...tart the timer Stop it Reset it to 00 hours 00 minutes 00 seconds and Sync it so that it only operates when in Monitor Play or Record mode and stops during Monitoring is Stopped or Paused For more inf...

Page 16: ...B RF Level A B and or AF Level Note Receiver parameters cannot be changed in this dialog to do so return to Monitor Mode and use the Channel Setup dialog see page 10 in this manual for more informati...

Page 17: ...ification by opening the Zoom menu available only in Time Domain Mode Spectrum Analyze Mode The third and final main mode of operation offered by WSM is Spectrum Analyze Mode In this mode WSM uses you...

Page 18: ...aphed onscreen as shown below The horizontal axis shows time elapsed while the vertical axis shows RF level in dB V Note that RX1 in the receiver specified in the Group Select dialog see previous page...

Page 19: ...d licensability depends on the user s classification application and frequency selected This device complies with RSS 210 of Industry Science Canada Operation is subject to the following two condition...

Reviews: