background image

12

Monitor Mode Tool Bar

WSM’s 

Tool Bar

provides graphic icons that allow you to carry out various operations with a single

mouse click.  Though available in all screens and in all modes of operation, you can opt to turn it on or off
by checking or unchecking the Tool Bar option in the Display menu (see page 13 for more information).
Not all Tool Bar icons are functional in all modes, however.  Those that cannot be used in a particular
mode of operation will be grayed out.  The illustration above shows the Tool Bar display when WSM is in
Monitor mode.

As you can see, there are a 

lot 

of Tool Bar icons.  Fortunately, there’s no need to actually memorize all

their functions (though you’ll find yourself remembering them quickly after you’ve used WSM a few
times), thanks to WSM’s 

Status Bar

.  To turn on the Status Bar, simply check it in the Display menu.

The bottom line of your screen (regardless of the mode you’re in) will now always show you the function
of each Tool Bar icon as you “roll over” it with your mouse.

File Tools - These icons are available in all screens and all modes of operation.  From left to
right, they allow you to create a new file; open an existing file, save the current data to disk;
and print the current screen.  For more information, see “File Menu” on page 13 of this manual.

Help Tools - These icons are available in all screens.  The left icon displays the WSM version number
and copyright information.  The right icon provides context-sensitive “pop-up” help information.  See
page 9 in this manual for more information about WSM online help.

Transport Tools - Available only in Monitor mode, these icons correspond to the options in the
Monitor menu.  They are, from left to right: Play, Stop, Pause, or Record data.  When you click on
Play, all onscreen meters become active although data is not recorded.  To stop monitoring, click
on Stop; to momentarily pause it, click on Pause.  To record data (which can be saved to disk
and/or displayed in Time Domain mode), click on Record Data will continue to accumulate until
you click on Stop.  For more information, see page 8 in this manual.

Setup Tools - Available only in Monitor mode, these icons correspond to the options in the
Setup menu, each calling up a dialog box.  They are, from left to right: Channel Setup,
Channel Plan Setup, Scene Memory Setup, Program Setup, and Simple Monitor Screen.
For more information, see “File Menu” on page 13 of this manual.

Window Tools - These icons are available in all screens.  They correspond to options in the
Window menu, each calling up a different mode of operation.  From left to right, they allow you to
select Monitor mode, Time Domain mode, and Spectrum Analyze mode.  For more information, see
“File Menu” on page 13 of this manual.

Summary of Contents for WSM Wireless System Manager for Windows 95

Page 1: ...OWNERS MANUAL Wireless System Manager for Windows 95 Windows and Windows logo are registered trademarks of Microsoft Corp...

Page 2: ...lvd P O Box 9031 Syosset NY 11791 9031 Phone 1 800 3 SAMSON 1 800 372 6766 Fax 516 364 3888 Table of Contents Introduction 1 Hardware Interconnections 1 Software Installation 5 Launching Wireless Syst...

Page 3: ...Samson Wireless System Manager ever require servicing a Return Authorization number RA is necessary Without this number the unit will not be accepted Please call Samson at 1 800 372 6766 for a Return...

Page 4: ...connector cable to the joystick MIDI port of your computer s Sound Blaster 16 card and the other end to the PC connection on the IF6P If you need to remote your receivers 20 feet or more from the com...

Page 5: ...mini DIN cables to connect the Remote Out of the first receiver to the Remote In of the next one daisy chain fashion Then connect the Remote Out of the last UR6D or UR6DX receiver to the IF6P 1 In If...

Page 6: ...h on the side of both the IF6P and IF6R to 2 Alternatively as shown in the illustrations on the right you can use standard mic cable with XLR connectors again up to 200 meters in length Plug the male...

Page 7: ...perties dialog opens click on the Advanced tab Open the MIDI Devices and Instruments folder and select MIDI for External MIDI Port Click on Properties and the MIDI For External MIDI Port Properties di...

Page 8: ...lling the WSM application you need to first copy the font file named Lucon onto your hard disk This file must be placed inside the Fonts folder in the Windows folder as shown in the illustration on th...

Page 9: ...eated WSM file if one exists WSM files contain the current channel setup all recorded data and the contents of all Scene Memories It then scans all connected receivers to check that all parameters in...

Page 10: ...g Condition from the Settings menu or click on the Drawing Condition icon in the Tool Bar In the resulting dialog select the appropriate receiver tab s then check the data type s you wish to view RF L...

Page 11: ...up menu select the Channel Plan option The Channel Plan dialog shown at right will appear Begin by specifying the number of channels you want to have included in the plan To have WSM generate a channe...

Page 12: ...ied by WSM RX1 and RX2 Titles Audio Frequency RX AF on off Tone Squelch T SQ on off when off the box is colored yellow Mute on off when on the box is colored red Antenna A Attenuation ATT A Antenna B...

Page 13: ...RF Level meter for each receiver This meter shows the RF signal strength being received by the antenna currently in use and the legend beside it shows whether the A or B antenna is the current one In...

Page 14: ...see File Menu on page 13 of this manual Help Tools These icons are available in all screens The left icon displays the WSM version number and copyright information The right icon provides context sens...

Page 15: ...tart the timer Stop it Reset it to 00 hours 00 minutes 00 seconds and Sync it so that it only operates when in Monitor Play or Record mode and stops during Monitoring is Stopped or Paused For more inf...

Page 16: ...B RF Level A B and or AF Level Note Receiver parameters cannot be changed in this dialog to do so return to Monitor Mode and use the Channel Setup dialog see page 10 in this manual for more informati...

Page 17: ...ification by opening the Zoom menu available only in Time Domain Mode Spectrum Analyze Mode The third and final main mode of operation offered by WSM is Spectrum Analyze Mode In this mode WSM uses you...

Page 18: ...aphed onscreen as shown below The horizontal axis shows time elapsed while the vertical axis shows RF level in dB V Note that RX1 in the receiver specified in the Group Select dialog see previous page...

Page 19: ...d licensability depends on the user s classification application and frequency selected This device complies with RSS 210 of Industry Science Canada Operation is subject to the following two condition...