86 | SAMLEX AMErICA INC.
Models
eVo-2212e
eVo-3012e
eVo-2224e
eVo-4024e
inVerter SeCtion
output waveform
Pure Sine Wave
input battery Voltage range
9.1 - 17 VDC
18.1 - 34 VDC
nominal AC output Voltage
230 VAC ± 5%
output Frequency
50 / 60 Hz ± 0.1 Hz (Default 50
±
0.1 Hz)
total harmonic Distortion of Pure
Sine wave Form (thD)
< 5%
Continuous output Power
2200 VA
3000 VA
2200 VA
4000 VA
Continuous AC output Current
10A
13A
10A
18A
Surge Power for 1 msec
300%
(6600 VA, 30A)
300%
(9000VA, 39A)
300%
(6600VA, 30A)
300%
(12,000 VA, 52A)
Surge Power for 100 msec
200%
(4400VA, 20A)
200%
(6000VA, 26A)
200%
(4400VA, 20A)
200%
(8000VA, 35A)
Power boost for 5 sec
150%
(3300W)
150%
(4500W)
150%
(3300W)
150%
(6000W)
Power boost for 30 sec
140%
(3080W)
140%
(4200W)
140%
(3080W)
140%
(5600W)
Power boost for 5 min
120%
(2640W)
120%
(3600W)
120%
(2640W)
120%
(4800W)
Power boost for 30 min
110%
(2420W)
110%
(3300W)
110%
(2420W)
110%
(4400W)
Maximum Continuous DC input
Current
266 A
373 A
133 A
266 A
inverter efficiency (Peak)
90%
90%
93%
94%
no Load Power Consumption in
Power Saving Mode
< 8 W
no Load Power Consumption in
normal Mode
30 watts
25 watts
AC inPut FroM griD / generAtor
AC input Voltage
230VAC (140 - /- 5% selectable)
AC input Frequency
50 Hz / 60 Hz (40 - 70 Hz selectable)
Maximum Programmable (Default)
AC input Current
5-20A
(Default 16A)
5-25A
(Default 16A)
5-20A
(Default 16A)
5-35A
(Default 16A)
trAnSFer ChArACteriStiCS
transfer relay type and Capacity
SPDT, 40A
SPDT, 40A
SPDT, 40A
SPDT, 40A
transfer time – inverter to grid /
generator
< 1 ms (Synchronized transfer at zero crossing)
transfer time – grid / generator
to inverter
Up to 16ms (Synchronized transfer)
SECTIOn 7 |
Specifications