54 | SAMLEX AMErICA INC.
SECTIOn 3 |
Installation
EVO INVERTER
CHARGER
Grounding
Terminal (5)
Fuse
Optional Remote
Control EVO-RC
To Remote Start/Stop
Terminals on the
Generator
Optional
Generator Auto
Start/Stop
Module
FRONT
(See Fig 2.1)
5
7
6
14
1
3
4
Fuse
(Within 7”
of battery
terminal)
NO - Normally Open Contact
Common
NC - Normally Closed Contact
14
A
B
C
B
A
C
2
+
-
+
-
Lead Acid
Battery Bank
Battery
Temperature
Sensor
- Model EVO-BCTS
External Battery Charger
Battery
-
Battery
+
AC SIDE
(See Fig 2.3)
12
11
10 8
4
5
7
9
6
ELECTRICAL SUB-PANEL FOR EVO
Panel for AC loads backed up by EVO
TM
N-B
RCD
L
L
N
N
L-B
PE-B
TO LOAD CIRCUIT
BACKED UP
BY EVO
TM
L
N
G
DC SIDE OF EVO
TM
1. Battery Positive
2. Battery Negative
3. External Charger Positive
4. External Charger Negative
5. Ground Terminal
6. RJ-45 Jack for Temperature Sensor
7. RJ-45 Jack for Optional Remote Control EVO-RC
14. Status Relay Terminals for initiating automatic
generator start / stop (”NO” & Common)
AC SIDE OF EVO
TM
4. GRID LINE
5. GRID GND
6. GRID NEUTRAL
7. GEN LINE
8. GEN GND
9. GEN NEUTRAL
10. OUTPUT LINE
11. OUTPUT GND
12. OUTPUT NEUTRAL
OTHER
Circuit Breaker
Fuse
L-B. Bus bar for Line conductors
N-B. Bus bar for Neutral conductors
PE-B. Bus bar for Protective Earthing (PE) conductors
PEN. Conductor with Protective Earthing (PE)
and Neutral (N) combined
RCD. Residual Current Device
L.
Line terminal
N.
Neutral terminal
G.
Grounding terminal
EG. Earthing terminal on Generator (Bonded to frame)
ME. Main Earthing terminal of the premises
RCD
L
N
L
N
230VAC GENERATOR
L
G
N
EG
MAIN AC DISTRIBUTION
PANEL OF THE PREMISES
RCD
L
L
N
N
L
Service
Cutout
of the
premises
N
L
PEN
ME
L-B
N-B
L
N
L
N
PE-B
Bonded to Ground Rod
or to buried metallic pipe
(water / gas) for Earth Ground
EG
Fig 3.13 typical Shore based installation for tn-C-S / Protective
Multiple earthing (PMe) Distribution System