SAMLEX AMERICA INC. | 57
APPENDIX A
TABLE 4.5 GROUP 3 PARAMETER SET UP: INPUT LOW LIMIT
Parameter
Setup Screen
No. for
Parameter
Group No.3
(Fig 4.1)
Parameter
Setting range
Default value
EVO-
2212
EVO-
3012
EVO-
2224
EVO-
4024
EVO-
2212
EVO-
3012
EVO-
2224
EVO-
4024
1
RESET VOLTAGE
60.0 – 120.0V
105.0V
2
CUT OFF VOLT 1
60.0 – 120.0V
100.0V
3
DETECT TIME 1
0 – 2000 cycles
300 cycles
4
CUT OFF VOLT 2
60.0 – 120.0V
95.0V
5
DETECT TIME 2
0 – 2000 cycles
15 cycles
6
CUT OFF VOLT 3
60.0 – 120.0V
90.0V
7
DETECT TIME 3
0 – 2000 cycles
1 cycle
4.6.2 Description of Parameters Under Group 3 – INPUT LOW LIMIT
i
INFO
The values shown under various screens are the Default Values for EVO-2212
4.6.2.1 RESET VOLTAGE
(Table 4.5, Parameter Setup Screen No.1)
This is the reset voltage at which the unit will revert to "Charging Mode" after it has switched over to "Inverting Mode"
due to input voltage falling to "CUT-OFF VOLT 1
(Section 4.6.2.2)
, or CUT-OFF VOLT 2
(Section 4.6.2.4)
, or CUT-OFF
VOLT3"
(Section 4.6.2.6)
.
4.6.2.1.1 Programming Steps for Parameter "RESET VOLTAGE"
Enter Key Up Key x 2 times Enter Key Enter Key
A N Y O P E R A T I N G
M O D E S C R E E N
ð
S E L E C T G R O U P
C H A R G E C U R V E
ð
S E L E C T G R O U P
I N P U T L OW L I M I T
ð
R E S E T V O L T A G E
1 0 5 . 0 V
ð
K E Y I N P A S S WO R D
0 0 0 0
Password 8052
See Section 4.3.1
ð
R E S E T V O L T A G E
1 0 5 . 0 V
4.6.2.2 CUT OFF VOLT 1
(Table 4.5, Parameter Setup Screen No.2)
If during "Charging Mode", the AC input voltage falls below "CUT-OFF VOLT 1" for period > "DETECT TIME 1"
(Section
4.6.2.3)
, the EVO™ Inverter/Charger will transfer to Inverting Mode from "Charging Mode".
4.6.2.2.1 Programming Steps for Parameter "CUT OFF VOLT 1"
Enter Key Up Key x 2 times Enter Key Up Key x 1 time Enter Key
A N Y O P E R A T I N G
M O D E S C R E E N
ð
S E L E C T G R O U P
C H A R G E C U R V E
ð
S E L E C T G R O U P
I N P U T L OW L I M I T
ð
R E S E T V O L T A G E
1 0 5 . 0 V
ð
C U T O F F V O L T 1
1 0 0 . 0 V
ð
K E Y I N P A S S WO R D
0 0 0 0
Password 8052
See Section 4.3.1
ð
C U T O F F V O L T 1
0 1 0 0 . 0 V
SECTION 4 |
Parameter Setup