![Sames inocoat Inogun A Instruction Manual Download Page 30](http://html1.mh-extra.com/html/sames/inocoat-inogun-a/inocoat-inogun-a_instruction-manual_3696802030.webp)
30
Member of Exel group
DRT7133
D - 2023/01
5.2.5. Installation of a 60° or 90° nozzle adapter
The
Inogun A
gun can be equipped with optional 60° and 90° nozzle adapters for flat spray and round spray
(
• Switch off high voltage,
•
Step 1
: Manually unscrew the nozzle nut (1).
•
Step 2
: Remove the electrode support assembly (3)
and its deflector (2) flat spray or round spray.
•
Step 3
: Screw the nut(4) of the 60° or 90° nozzle
adapter onto the barrel of the
Inogun A
.
•
Step 4:
Install the electrode support assembly (3) and
its deflector (2) flat spray or round spray on the 60° or
90° nozzle adapter.
•
Step 5:
Screw the nozzle nut (1) onto the adapter by
hand.
• Restart the high voltage supply.
3
2
1
4
2
3
1