9
Member of Exel group
DRT7142
B - 2023/06
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation resistance measured
must not exceed 100 M
Ω
.
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the insulation resistance
measured must not exceed 100 M
Ω
.
3 Make sure that the pneumatic pressure inside is completely exhausted before adjusting or servicing
pressurized systems or parts.
4 Using individual protection equipment will limit the risks of contact and/or inhalation of toxic product, gas,
vapours, fog or dusts that can be produced while using the equipment. The user has to follow the coating
product manufacturer’s recommendations.
5 Appropriate measures must be taken to prevent potential energy being present in the equipment during
periods of non-use and/or when the equipment is out of service.
6 The
Inocenter
powder station must be maintained regularly in accordance with the indications and instructions
given by
Sames
. Repairs must be carried out in strict accordance with these instructions.
7 Unplug, lock out and turn off electrical equipment before servicing electrical equipment.
8 Turn off all electrical or electrostatic equipment immediately, even if the operator is exposed to a slight electric
shock. Do not restart the equipment until the problem has been diagnosed and resolved.
9 The powder station, especially the vibrating table and all conductive structures placed in or near the work place
must be electrically connected to the protective grounding system of the power supply.
10All grinding or welding work on metal products carried out at a distance of less than 5 meters from the powder
station is prohibited if the following safety measures are not observed
• The powder station must be protected by a cover made of non-flammable (or hardly flammable) material.
• A person equipped with a fire extinguisher must monitor the environment of the powder station during the
work.
11The powder station must not support a mass other than that of the equipment originally intended to be
mounted on or around it. The structure of the powder station is self-supporting. In no case is the powder station
designed to support the mass of an operator working on its roof, the mass of a part of the building or any other
load.
12The floor on which the power plant is installed must have a strength of more than 400 kN/m
2
.
13 Do not bring corrosive products or objects likely to deteriorate its surface into contact with the powder station.