2.5. Operating principles
2.5.1. Powder equipment
The
Inocenter
powder unit is part of the
Sames
powder range.
2.5.2. New powder supply
The supply of new powder starts when the tank is filled for the first time, and in the production phase when the high
level sensor is lost, followed by an adjustable delay. The pump transfers the powder from the container to the tank.
Sleeve valve QR11 open and sleeve valve QR23 closed.
DES09280
KK511
KK523
QR23
QR11
KK23
N225
Powder tank
Air tank
Powder
pump
Powder
box
Powder flow