4.2.7. Setting the air regulators
4.2.8. Level sensor fluidization air setting
Level sensor fluidization air is regulated using air restrictors. The air supply to the fluidizing plates of the level sensors
is shared with the fluidizing air from the powder tank.
• Raise the powder level above the sensor.
• Maintain powder level for 1 to 2 minutes.
• Adjust the air restrictors to ensure a gentle flow of air over the front of the level sensors..
• By lowering the level of powder below the sensors, check that there is no agglomerate of powder on the sensor
and that it has detected an absence of powder.
• The setting is complete.
4.2.9. Installation of solenoid valves for booth floor blower (option)
•
Step 1
: Screw the mounting plate to the profile at
the rear of the Inocenter (under the tank blowing
solenoid valve assembly) using two M8x20 screws
(1).
•
Step 2
: clip the solenoid valve assembly onto the rail
of the mounting plate.
Connect the hoses to the solenoid valves.
Regulator number
Designation
Type of regulator
Factory setting
KH20
Regulator for plunger feed sleeve valves
0-6bar
4 bar
KH21
Ventilation damper and tank valve regulator
0-6bar
4 bar
KH22
Fluidizing air adjustment (to ensure bubbling
without excessive smoke)
0-6bar
0.8bar - 1.5bar
KH23
Transfer pump sleeve valve regulator
0-6bar
4bar
KH24
Transfer pump conveying air regulator
0-6bar
0.8bar - 1.5bar
KH25
Floor supply air regulator
0-6bar
4bar
KH26
Fire detection regulator
0-4bar
1bar
KH225
Cleaning air regulator
0-6bar
4.5bar