34
Member of Exel group
DRT7142
B - 2023/06
5.3.4. Procedure D1: Replacement of the porous plate and flat seal on the tank bottom
Disassembling
:
•
Step 1
: disconnect the air and powder hoses at the
rear of the tank, as well as the electrical cables.
•
Step 2
: loosen the 4 M6x12 screws on the flange (
2
)
at the rear of the tank to remove the cylinder bellows
(
1
).
•
Step 3
: remove the two side bars (
6
) holding the
venturi pumps by slightly loosening the 4 lock nuts
(
5
), unscrewing the 4 M6x25 screws (
4
) and removing
the 4 pins (
3
).
•
Step 4
: disconnect the powder hoses from the venturi
pumps at the bottom of the tank.
Unclip the venturi pumps from the tank and
temporarily tie the venturi pumps and their hoses
together on each side of the tank, to make it easier to
move the tank.
•
Step 5
: on the roof of the Inocenter, next to the light
fitting, disconnect the two level sensor cables (
7
).
Loosen the two bulkhead unions at the rear of the
tank and bring the cables forward about 20 cm to
avoid straining them when the tank is lifted.
3
2
4
5
6
1
7