DRT7142
B - 2023/06
3.3. Noise level
3.3.1.
Inocenter
in operation phase
The weighted equivalent continuous sound pressure level is 79 dB (A) under the specified operating conditions.
Measuring conditions: the equipment was put into operation at maximum characteristics, the measurements were
carried out at different positions at 1 m from the powder station and on the side accessible by the user in the powder
laboratory on the
Sames
site in Meylan, France.
Method of measurement: The weighted equivalent sound pressure level of 79 dB (A) is in LEQ value, measured over
observation periods of at least 30 seconds.
3.3.2.
Inocenter
in cleaning phase
The weighted equivalent continuous sound pressure level is 99 dB (A) under the specified operating conditions.
Measuring conditions
: the equipment was put into operation at maximum characteristics, the measurements were
carried out at different positions at 1 m from the powder station and on the side accessible by the user in the powder
laboratory on the
Sames
site in Meylan, France.
Method of measurement
: The weighted equivalent sound pressure level of 99 dB (A) is in LEQ value, measured
over observation periods of at least 30 seconds.