21
Member of Exel group
DRT7142
B - 2023/06
2.5.12. Blowing tank, pap and cyclone
Blowing through the QR23 & QR24 valves cleans all the powder pipes.
1 Blowing towards the cyclone via QR24 and KK24 (QR48 & QR10 closed).
2 Blow to tank via QR24 and KK24 (EVM21 & QR48 closed).
3 Blowing of the recycling duct (which is used during the recovery phase of the powder contained in the cyclone)
by QR48 (QR10 & EVM21 closed).
4 Blowing via QR23 and KK 23 to the reservoir (PAP sleeve valves closed).
5 Blowing towards the PAP (QR11 closed).
DES09290
KK24
KK23
KK548
KK523
KK524 KK510
QR48
QR24
QR10
QR11
N225
EVM22
Air T21A
Air T22A
EVM21
QR23
Powder
tank
Air flow
Evacuation to
ventilation
Powder supply
plunger in its
housing
along the
powerstation
Air tank
Manual connection
(quick connector)
ventilation or recycling
Powder
box
Powder
pump