Index revision : A
9
7159
WARNING :
Equipment should only be used in well-ventilated areas to reduce health, fire and explosion
hazards. The effectiveness of the exhaust ventilation system should be checked daily.
Within explosive atmospheres produced by the spraying process, only appropriate explosion-
proof electrical equipment has to be used.
1 The operator must wear shoes according to standard EN ISO 20344 and the insulation
resistance measured must not exceed 100 M
Ω
.
2 The protective clothes, including gloves, must conform to standard EN 1149-5 and the
insulation resistance measured must not exceed 100 M
Ω
.
3 Using individual protection equipment will limit the risks of contact and/or inhalation of
toxic product, gas, vapours, fog or dusts that can be produced while using the equip-
ment. The user has to follow the coating product manufacturer’s recommendations.
4 Contact or inhalation of the products used with this equipment may be dangerous for
personnel (see: safety data sheets for the products used). The pressure coating material
or compressed air must not be directed at people or animals.
5 All conductive structures such as floors, powder spray station walls, ceilings, barriers, bar-
riers, parts to be painted, powder dispensing tank placed in or near the work area and
the ground terminal of the electro-pneumatic control module must be electrically
connected to the grounding system for protecting the power supply.
6 The floor on which the operator works must be dissipative (bare concrete floor or metal
grating). Never cover the floor with an insulating covering. In potentially explosive loca-
tions, floor assemblies must be dissipative in accordance with EN 61340-4-1.
7 Switch off the power supply to the Inobox before connecting the "Inogun M" gun.Before
disconnecting the gun, cut off the power supply to the Inobox (otherwise a malfunction
may occur).
8 Never point the gun at a person or animal.
9 Powder spraying must be carried out in front of a ventilated station provided for this
purpose. The activation of the Inobox must be controlled by the operation of the venti-
lation system. The correct operation of the drive must be checked once a week.
10 The ambient operating temperature must be between 0 and 40°C.
11 The electrostatic powder spraying equipment must be maintained regularly in accor-
dance with the indications and instructions given by
SAMES KREMLIN
.
Repairs must be carried out in strict accordance with these instructions.
12 The electrostatic powder spraying equipment should only be operated if it is in perfect
condition. Damaged equipment must be removed from service immediately and repai-
red.