Data mapping for Modbus only
Write/Read
Address
Description
Type
Size
Unité
R
30002
Machine state
unsigned word
16 bits
-
R
30003
Production flow
unsigned word
16 bits
cc * 10/min
R
30004
Ratio A/B
unsigned word
16 bits
ratio * 100
R
30005
Current recipe
unsigned word
16 bits
-
R
30006
Potlife 1
unsigned
double word
32 bits
sec
R
30008
Potlife 2
unsigned
double word
32 bits
sec
R
30010
Faults_1
unsigned word
16 bits
-
R
30012
Faults_2
unsigned word
16 bits
-
R
30013
Ratio A/C
unsigned word
16 bits
ratio * 100
R
30014
A consumption
unsigned
double word
32 bits
cc
R
30016
B consumption
unsigned
double word
32 bits
cc
R
30018
C consumption
unsigned
double word
32 bits
cc
R
30020
A consumption
saved
unsigned
double word
32 bits
cc
R
30022
B consumption
saved
unsigned
double word
32 bits
cc
R
30024
C consumption
saved
unsigned
double word
32 bits
cc
W
30039
PLC_Command_1
unsigned word
16 bits
-
W
30040
PLC_Command_2
unsigned word
16 bits
-
R
30041
Flag_1
unsigned word
16 bits
-
R
30042
Flag_2
unsigned word
16 bits
-
Summary of Contents for Cyclomix Evo
Page 1: ...Instruction manual DRT582165110 A 2023 03 Cyclomix Evo ...
Page 83: ...83 Member of Exel group DRT582165110 A 2023 03 3 2 2 Main box dimensions ...
Page 103: ...103 Member of Exel group DRT582165110 A 2023 03 ...
Page 104: ...104 Member of Exel group DRT582165110 A 2023 03 4 3 2 Network overview ...
Page 106: ...106 Member of Exel group DRT582165110 A 2023 03 4 4 3 Installation of boxes ...
Page 122: ...122 Member of Exel group DRT582165110 A 2023 03 5 2 14 2K gun overview complete option ...
Page 123: ...123 Member of Exel group DRT582165110 A 2023 03 5 2 15 3K gun overview complete option ...
Page 149: ...149 Member of Exel group DRT582165110 A 2023 03 9 Appendixes 9 1 Preventive Maintenance Plan ...
Page 167: ...151 Member of Exel group DRT582165110 A 2023 03 ...
Page 168: ...152 Member of Exel group DRT582165110 A 2023 03 ...