The circuit
2 or 3 possible choices depending on the configuration:
• Machine and mixer.
• Gun hose 1.
• Gun hose 2.
If...
Then...
If the circuit is defined as Machine and
Mixer.
Therefore, this flushing step will be systematically performed
regardless of the gun(s) used during the production phase.
production phase.
If the circuit is defined as Gun hose 1
So, this step will be performed only if the gun 1 has been used
during the production phase.
If the circuit is defined in Gun hose 2
So, this step will be performed only if the gun 2 has been used
during the production phase.
If the Cyclomix
®
Evo is defined with 2 guns.
Therefore, it is preferable to define a flushing step with the hose
gun 1 and a flushing step with the hose gun 2.
If no flushing step is set for a gun.
Then it will not be possible to start production with this gun. When
selecting the gun, an error message will appear to inform the user
that no flushing step is defined for this gun.
Summary of Contents for Cyclomix Evo
Page 1: ...Instruction manual DRT582165110 A 2023 03 Cyclomix Evo ...
Page 83: ...83 Member of Exel group DRT582165110 A 2023 03 3 2 2 Main box dimensions ...
Page 103: ...103 Member of Exel group DRT582165110 A 2023 03 ...
Page 104: ...104 Member of Exel group DRT582165110 A 2023 03 4 3 2 Network overview ...
Page 106: ...106 Member of Exel group DRT582165110 A 2023 03 4 4 3 Installation of boxes ...
Page 122: ...122 Member of Exel group DRT582165110 A 2023 03 5 2 14 2K gun overview complete option ...
Page 123: ...123 Member of Exel group DRT582165110 A 2023 03 5 2 15 3K gun overview complete option ...
Page 149: ...149 Member of Exel group DRT582165110 A 2023 03 9 Appendixes 9 1 Preventive Maintenance Plan ...
Page 167: ...151 Member of Exel group DRT582165110 A 2023 03 ...
Page 168: ...152 Member of Exel group DRT582165110 A 2023 03 ...