SAMES KREMLIN
Page 16
Manual : 573.176.112
Parameters listed below only correspond to specific REGULEX® shot meters :
P 02, P 03, P 05, P 09, P 18, P 24, P 25, P 26.
Incorrect adjustment of these parameters will cause the REGULEX
®
shotmeter to
malfunction and may cause damage.
REGULEX® version
Stroke
P 03
Low
position
(mm)
P 05
High
position
(mm)
P 09
Low
position
(mm)
P 18
Piston
section
(mm2)
P 02
Pressure
(bar)
P 24
Pressure
sensor
(bar)
P 25
Position
sensor
(mm)
P 26
Kind of
valves
Type : compacted
2
25
23
5
20
71
45
50
25
0
5
25
23
5
20
198
45
50
25
0
25
13
11
5
8
2205
45
50
25
0
50
25
23
5
20
2205
45
50
25
0
Type : reinforced, white case
47 D 220V
50
48
5
40
961
60
100
50
1
47 D 24V
50
48
5
40
961
60
100
50
1
100 D 220V
50
48
5
40
2155
45
100
50
1
100 D 24V
50
48
5
40
2155
45
100
50
1
Type : reinforced, blue case
47 R 220V
50
48
5
40
961
100
150
50
1
47 R 24V
50
48
5
40
961
100
150
50
1
107 R 220V
50
48
5
40
2155
80
150
50
1
107 R 24V
50
48
5
40
2155
80
150
50
1
7 R 24V
50
48
5
40
198
100
150
50
1
27 R 24V
50
48
5
40
642
100
150
50
1