SAMES KREMLIN
Page 19
Manual : 573.176.112
PARAMETER 09 : PISTON LOW POSITION LIMIT DURING THE REGULATION STAGE
(position limit that the REGULEX® piston shall not exceed during the regulation stage)
Mini. limit (mm)
Maxi. limit (mm)
Value for the first operating (mm)
00.0
50.0
08.0
That position preset after test enables the detection:
- a valve leak,
- air presence in the
REGULEX
® chamber.
PARAMETER 10 : PRESSURE TOLERANCE FOR THE REGULATION OPERATION
(Tolerance between theorical pressure and real pressure at the beginning of extrusion to vet the
READY signal)
Mini. limit (%)
Maxi. limit (%)
Value for the first operating (%)
01
20
10
Example : - If the value of the parameter is increased
the Ready signal ` is validated more quickly
- If the value of the parameter is decreased
The quality of the bead is improved
PARAMETER 11 : FLOW INSTRUCTION FILTER
(
limits the uncontrolled variations of bead diameter due to interferences on the ROBOT-REGULEX®
connection)
Mini. limit
Maxi. limit
Value for the first
operating
Recommended value
01
20
10
20
Example : If the value is to 20% :
-
above this threshold
the flow variation is considered
- below this threshold
the flow variation is not considered
Caution : We use this parameter in analogue mode only.
PARAMETER 12 : MAX. PERIOD FOR FLOW MODIFICATION
(necessary time to change the bead variation expressed by torque of 50 ms)
Mini. limit
Maxi. limit
Value for the first operating
01
20
10
Example : - 01 = 50 ms.
- 20 = 1sec.
PARAMETER 13 : SERVO-CONTROL GAIN DURING THE FLOW MODIFICATION STAGE
(defines the pressure servo-control features during the flow variation stage)
Mini. limit (%)
Maxi. limit (%)
Value for the first operating (%)
01
99
10
PARAMETER 14 : MAX. FLOW COEFFICIENT
(defines the maximum flow obtained when the robot information is at 100% of its value)
Mini. limit
Maxi. limit
Value for the first operating
01
99
10