12- ADJUSTMENT OF THE OFFSETS - CALIBRATING THE B6 CONTROL UNIT
AND THE REGULEX®
This operation is necessary to calibrate and synchronise the B6 REGULEX® control unit with the
REGULEX® shotmeter.
It consists of resetting to zero of the pressure transducer and the position sensor / linear tranducer.
These adjustments are made :
On the B6 control unit,
On the sensors,
On the REGULEX® shotmeter.
Offset Page
This page, gives you access to the following functions :
- Back to the manu page
- Recalibrating the sensors.
The '
' and '
' keys enable the selection of a parameter between the 4 available.
The 4 available parameters are :
Pressure sensor Regulex A
Position sensor Regulex A
Pressure sensor Regulex B
Position sensor Regulex B
The parameters are associated to a commentary on the function.
The commentary and the offset values are written in editing mode in the frame provided for that purpose.
The digital keyboard is not active in that mode.
All the parameters are available in reading and modification.
On two columns, the previous stored value and the sensor raw value (without offset compensation); the
display is made in physical quantity (bar and mm).
Only one input on the '
' key vets the sensor current value as a new origin. The limiting control is in
conformity with the previous version. If fault, a message is displayed in the Fault zone.
Pressure sensor Channel A : Offset automatic compensation on pressure sensor channel A (bar)
Position sensor Channel A : Offset automatic compensation on position sensor channel A (mm)
Pressure sensor Channel B : Offset automatic compensation on pressure sensor channel B (bar)
Position sensor Channel B : Offset automatic compensation on piston position sensor channel B (mm)