SAMES KREMLIN
Page 18
Manual : 573.176.112
PARAMETER 03 : LOWER PISTON LIMIT
(position that the REGULEX® piston must never pass during the extrusion (manual or automatic) in
order to avoid a bottoming out)
Mini. limit (mm)
Maxi. limit (mm)
Value for the first operating (mm)
1.0
50.0
11.0
PARAMETER 04 : MAXIMUM FILLING TIME
(when the filling begins, a timer of the value adjusted to the parameter 04 is activated)
Mini. limit (sec.)
Maxi. limit (sec.)
Value for the first operating
(sec.)
10.0
99.9
99.9
PARAMETER 05 : POSITION AT WICH THE REGULEX IS CONSIDERED FILLED
(position of the REGULEX® at which it is considered filled)
Mini. limit (mm)
Maxi. limit (mm)
Value for the first operating (mm)
00.0
50.0
05.0
The adjustment of the position provides:
- the volume of glue or mastic, necessary for the dispensing,
- a possible backward movement of the piston to depressurize the material located in the chamber before
reaching the piston upper stop (stop located at 1 mm of the maximum high position).
PARAMETER 06 : MIN. FEEDING PRESSURE
(
Pressure at which the material supply starts)
Mini. limit (bar)
Maxi. limit (bar)
Value for the first
operating (bar)
Recommended value
00.0
25.0
02.0
00.1
This parameter defines the speed of ascension of the piston in feeding : the lower the pressure is, faster is the
feeding
Caution : The pump supplying the REGULEX® must give the material flow.
PARAMETER 07 : SERVO-CONTROL GAIN IN PRESSURE DURING THE FILLING STAGE
(Speed of acceleration of the servo motor allowing acceleration or deceleration during filling)
Mini. limit
Maxi. limit
Value for the first operating
01
99
10
This parameter defines the speed of the piston ascent during the filling stage : the higher the servo-control is,
the faster the piston goes up.
Example : If the value is to 10 and that the feeding is not fast enough
change the parameter
value to 20 to accelerate the feeding.
Caution : The pump feeding the REGULEX® must be able to supply material at the correct volume.
PARAMETER 08 : SERVO-CONTROL GAIN IN PRESSURE DURING THE REGULATION STAGE
(Acceleration gain of the motor allowing the chamber to reach the regulated pre-pressure [SENDING
THE ‘READY’] SIGNAL)
Mini. limit
Maxi. limit
Value for the first operating
01
99
10