Doc.-ID: 180516-PT10BA-ES-RoughCam IPM1145-(L)_en_rev.01.docx, page 30 of 40
For the execution with a „K2“ cable gland, 7 x cylinder head screws M4 x 0.7 (ISO metric
right-hand thread) with a thread length of 30 mm are used.
Attention!
Do not lock-in any foreign objects inside the housing!
Attention!
The cylinder head screws for the connection of the housing body and
the flange have to be tightened with a torque of 3 Nm! Tighten the
screws in a crosswise sequence.
Please make sure that the disassembled screw locks (washer spring DIN 127A) are re-
assembled.
The GYLON® flat sealing must be intact and has to be reassembled according to the
hole-pattern of the flange. There is no restriction regarding the installation direction of the
sealing.
If, when closing the housing, it is noted that the surface of the joint is dirty or not lubricat-
ed sufficiently, please clean it with a clean cloth and suitable cleaning detergent. After-
wards, re-lubricate it with a suitable lubrication agent (e.g. Molykote® P-40 paste for
standard applications or special lubrication agents such as OKS 403 for seawater envi-
ronments
The screw connection of the flange and housing have to be tightened in crosswise se-
quence with a torque of
3 Nm
. Please avoid extensive tightening
– this might lead to a
torn screw.
For the fixed installation of the RoughCam IPM1145-(L), either with a wall mount bracket,
with a hinge attachment for sight-glass installations or for the optional installation of a
roof, please observe the instructions of the installation manual! Additional accessories
are available upon request.