Doc.-ID: 180516-PT10BA-ES-RoughCam IPM1145-(L)_en_rev.01.docx, page 10 of 40
- Includes a particularly developed chloroprene
rubber adapter for limiting the scattering an-
gle due to infrared light reflections within the
pressure resistant housing (q.v. optimization
of shadowing and interferences due to multi-
ple LED light reflections at the borosilicate
sight glass of the stainless steel housing)
- Radiation angle: Max 30°
Figure 2.1
– RoughCam IPM1145-L
2.7
Temperature range (MTBF)
2.7.1
RoughCam IPM1145(-L) PoE+
Permitted functional ambient temperature (MTBF)
4
: -30 °C to +40 °C (type L)
2.7.2
RoughCam IPM1145
Permitted functional ambient temperature (MTBF)
0 °C to +40 °C (type N)
0 °C to +70 °C (type H) (T5)
-30 °C to +40 °C (type L)
-60 °C to +40 °C (type LL)
-30 °C to +70 °C (type LH) (T5)
2.7.3
RoughCam IPM1145-L
Permitted functional ambient temperature (MTBF)
0 °C to +40 °C
(type N)
Axis M1145-L
0 °C to +65 °C (type H) (T5)
-30 °C to +40 °C
(type L)
-60 °C to +40 °C
(type LL)
-30 °C to +65 °C
(type LH) (T5)
4
Functional temperature range concerning the operational temperature range of the installed non-Ex components according to AXIS
manufacture declarations (MTBF
– mean time between failures) under consideration of thermal power loss and the temperature coef-
ficient of the housing.