functioning of the operating device in accordance with this user man-
ual and all other applicable regulation has been executed
Attention!
Incorrect installation and operation of the camera may lead to a loss of
warranty!
Attention!
When commissioning the camera at temperature below 0°C, it has to
be secured that the camera is not switched-on prior to the housing
heating. The PTC heating has to warm up the housing before turning
on the camera. This can be realized, for example, by the means of an
external time relay.
5.3
Testing of the status LED
The
camera module’s status LED is located in the back of the stainless steel enclosure
and is only visible when the housing is open.
The status of the RoughCam IPM1145-(L) is reflected by the LED indicators is as follows:
Status LED
Operation mode
Color
Comment
Green
At normal operation, a constant green light shows
Note: It is possible to configure the status LED in such a manner that in
normal operation it is not illuminated or only blinks when the camera is
accessed
Yellow
It is illuminated permanently when the camera is turned on as well as
when the camera is set back to default settings
Red
In case of an activation failure the light blinks slowly
Usage of the focus
assistant
n.a.
Table 5.5
– Status and control LED
5.4
Step 3: Adjusting the lens
Parametrization measures at the lens of the RoughCam IPM1145-(L) are exclusively
done via the Web Interface or the visualization software. Mechanical adjustments at the
varifocal lens by the user are not possible. The camera models RoughCam IPM1145 and
RoughCam IPM1145-L dispose of a so called
„remote Zoom“ functionality (q.v. figure
5.8)
The remote zoom function is less capable than a motor zoom lens (slower response time,
lower range) but more compact. It allows the user making the final settings via the com-