![Salvis ProfiLine 2-Flame gas hob Operating Instructions Manual Download Page 39](http://html1.mh-extra.com/html/salvis/profiline-2-flame-gas-hob/profiline-2-flame-gas-hob_operating-instructions-manual_804149039.webp)
en
39 / 72
9.1.2
Gas hob nozzle table
Determine the categories/types of gas, refer to page 38 Chapter 9.1.1!
Type of gas
Gas pressure
Burner
rating
External nozzle
Fine-adjust
ment nozzle
Replace
page 40
Chapter9.3
Pilot burner
nozzle
Replace
page 40
Chapter9.4
Natural
gas
G20
2E
2H
20 mbar
5.5 kW
Ø 1.85 mm
Primary air 2 mm
Release by ½
turn
Ø 0.35 mm
10 kW
Ø 2.35 mm
Primary air 2.5 mm
Release by ¾
turn
Ø 0.35 mm
Natural
gas
G20/25
2E+
20/25
mbar
5.5 kW
Ø 1.85 mm
Primary air 2 mm
Release by ½
turn
Ø 0.35 mm
10 kW
Ø 2.35 mm
Primary air 2.5 mm
Release by ¾
turn
Ø 0.35 mm
Natural
gas
G25
2LL
20 mbar
5.5 kW
Ø 2.00 mm
Primary air 2 mm
Set
Ø 0.35 mm
10 kW
Ø 2.60 mm
Primary air 2.5 mm
Set
Ø 0.35 mm
Natural
gas
G25
2L
25 mbar
5.5 kW
Ø 1.90 mm
Primary air 2 mm
Set
Ø 0.35 mm
10 kW
Ø 2.45 mm
Primary air 2.5 mm
Set
Ø 0.35 mm
Liquid gas
G30/G31
3+
28-30/
37 mbar
5.5 kW
Ø 1.15 mm
Primary air fully open
Ø 0.60 mm
Ø 0.25 mm
10 kW
Ø 1.50 mm
Primary air fully open
Release by ½
turn
Ø 0.25 mm
Liquid gas
G30/G31
3B/P
30 mbar
5.5 kW
Ø 1.15 mm
Primary air fully open
Ø 0.60 mm
Ø 0.25 mm
10 kW
Ø 1.50 mm
Primary air fully open
Release by ½
turn
Ø 0.25 mm
50 mbar
5.5 kW
Ø 1.10 mm
Primary air fully open
Ø 0.50 mm
Ø 0.25 mm
10 kW
Ø 1.35 mm
Primary air fully open
Release by ½
turn
Ø 0.25 mm