Ignite the pilot light and burner
DANGER! If there is a smell of gas in the room where installed, do not ignite the gas
flame!
Risk of explosion!
.
Shut off the gas tap on site!
.
Do not switch on or off electrical appliances!
.
Open windows and doors! Thoroughly ventilate the room where installed with a
draught!
.
After sufficient ventilation, determine the location of escaping gas!
.
Inform the standby service of the gas supplier!
● When the appliance has not been used for a
longer period of time: e. g. the main shut-off
device was closed, it may take slightly longer
before the pilot light ignites (the gas supply
has to fill up with gas again).
.
Press in and hold the gas control, turn to igni
tion symbol
.
.
Using the gas igniter, ignite the pilot light.
.
After igniting the pilot light, keep the gas con
trol pressed for approx. 5 - 10 seconds,
‒ so that the thermocouple can sufficiently
heat up and
‒ the gas supply is not automatically shut off
again (automatic safety pilot).
Set the burner flame
.
After ignition, release the gas control, lightly press and turn to high heating capacity.
.
To set from high to small flame, lightly press the gas control and turn to the small flame symbol.
● Low heating capacity, small flame symbol
● High heating capacity, high flame symbol
Pilot light - under the
pilot burner cover
Gas igniter
Gas control for burner, front