en
35
3.1
Display field and function keys
Button “Start/Stop”
(timer
option)
−
Start or stop short time
clock
−
Lower/raise lifting device
−
Change the basic settings of
the short time clock
Button “on/off”
−
Press the button for
three seconds to switch
on/off.
Button “P” in combination with other
buttons
−
temperature selection (buttons 1, 2, 3
and 4)
−
Change the saved temperature
−
Display of the grease utilisation period
−
Setting parameters
Up“button”
Display
(timer option)
−
Time in minutes and seconds
−
Parameter number
The indicator light glows when
the pump is switched on
(option).
The indicator light glows when
the automatic basket lift is
switched on (option).
“Temperature/Pump button”
(pump option)
−
Query the actual-temperature when the appliance
is switched on.
−
Switch the pump on and off, only if the appliance
has been switched off via the“on/off”switch.
Display
−
Setpoint- or actual-temperature
−
Grease utilisation period (timer option)
−
Parameter values (timer option)
−
Error number
Down“button”
In steps of 1 or 5, depending
on the setting in Chapter
Point glows
when the heater is on,
Point blinks
during the heating process if
the actual-temperature is more
than 10
°
C lower than the
setpoint-temperature.
Wait and do not start the deep
frying process until the point
goes off!
Button 1 and 2 for left lifting
device
Button 3 and 4 for right
lifting device
Only for appliances with two lifting devices in one bowl:
Buttons “1, 2, 3 and 4”
−
time/temperature
−
Selection of short time clock (timer option)
−
Terminate the acoustic signal,
−
Selection of the temperature
The indicator lights in the buttons
−
light up when the short time clock is switched on,
−
blink when the short time clock runs out.
Change buttons and acoustic signals
(timer option)
You can switch the buttons and acoustic signals on and off and change the duration of the acoustic signals, see starting on page 45
Dual bowl deep fat fryer
Pump option can only be ope-
rated via the left control panel.
Observe the waiting period between setting or query processes
Wait approx. 3 seconds between
different settings or query processes. For example
−
between setting the setpoint-temperature and
−
displaying the actual-temperature.
The control is only ready for a new setting or request action after expiry of this waiting period.