Tel: 886.909 602 109 Email: [email protected]
19
Config:
set the function of power supply
System set:
set the system parameter
List Set:
set list operation
Auto test:
set auto test operation
Output Timer:
set the duation of output
SN:
the serial number of the power supply
Exit:
exit the first-level menu
When accessing to
Config
item, the following menu items will be displayed on the VFD display screen by
pressing the keys ▲ and ▼.
Init:
set all settings to factory default set
Out Memory:
set the power supply’s output state when it is powered on
TRI KeepOut:
set
TRI
as preseved output port
Fast Recall:
set key shortcut function
Key Sound:
set the key sound
Knob Lock:
set the knob lock state
On
Setting the same state as last time you turned off the
power supply.
Off(Default)
Setting the output to OFF state when the power
supply is powered on.
On
When TRI is in low voltage level, the output state of
power supply is ON.
When TRI is in high voltage level, the output state
of power supply is OFF.
When the TRI KeepOut is enabled, the ON/OFF on
the front panel is invalid.
The TRI Keepout is only valid to ordinary operation
mode. It is invaid to list opeartion and auto test
mode.
Off(Default)
Disabled
On
In the main interface (not enter any menu of the
power supply), press the key 0~9 to recall
the parameters set by
Save
function
Off(Default)
Disabled
On(Default)
The buzzer will sound when any key was pressed.
Off
The buzzer will not sound when any key was
pressed
On
The knob is locked and rotating the knob will not
cause any change of the setting value.
Off(Default)
The knob is unlocked and rotating the knob will
cause change of the setting value.