35
Parameter: mode has three following modes,
FIXed
command set mode
LIST
sequential list mode
DRM
milliohmmeter mode
Return command: None
Example:
Sending command
[:]MODE LIST
, the power supply is in sequential list mode.
2. Related command
[:] MODE?
, to query working mode of power supply.
Return command parameter: <mode>
Command [:]VOLTage <Value>
1.This command is used to set the voltage value of power supply.
Parameters: numeric |MAX|MIN
Unit: V
Return Command: None
Example:
1) Sending command
[:]VOLT 30
Means to set the voltage value of the power supply is 30V.
2) Sending command
[:]VOLT MAX
Providing the maximum output voltage is 76.000V, it means to set the voltage value is the maximum voltage
76.000V.
3) Sending command
[:]VOLT MIN
Providing the minimum output voltage is 0.000V, it means to set the voltage value is the minimum voltage
0.000V.
2.Related Command
[:]VOLT? MAX|MIN
, the command is used to query the setup voltage value, the
maximu setup voltage value and the minimum setup voltage value.
Return command parameters: numeric
Example:
1) If you want to query the setup voltage value, please send command
[:]VOLT?
, if the return command is
10.0000, it means the setup voltage of power supply is 10.0000V.
2) If you want to query the maximum setup voltage value, please send command
[:]VOLT? MAX
, if the return
command is76.0000, it means the maximum setup voltage value of power supply is 76.0000V.
3) If you want to query the minimum setup voltage value, please send command
[:]VOLT? MIN
, if the return
command is 0.0000, it means the minimum setup voltage value of the power supply is 0.0000V.
Command [:]CURRent <Value>
1. This command is used to set the current value.
Parameters: numeric |MAX|MIN