ENGLISH

13

The motors are equipped with thermal motor protection, which
switches off the motor automatically if it overheats and
switches it on again when it has cooled down. The condenser
is integrated in the single-phase motor. 

Version with turbulator (Systéme SAN)

For waste water with precipitating and floating particles, the
submersible pump has been equipped with a turbulator at the
suction strainer. Precipitating particles are continuously whirled
up in the suction area of the pump and pumped off with the
water. Therefore, mud accumulation in the pump shaft, with
problematic consequences such as clogging of the pump and
odour formation, is largely prevented.

If the removal of the waste water does not allow any interrup-
tion, a second pump (automatic standby pump), together
with the necessary switchgear (accessory), increases the oper-
ating reliability if the 1st pump develops a fault.

7. INSTALLATION AND ELECTRICAL CONNECTION

DANGER! Risk of fatal injury!
Incorrect installation and improper electrical connec-
tions can result in a risk of fatal injury. 

•The installation and electrical connections should only 

be done by properly skilled staff and in compliance 
with the applicable regulations!

•Follow all accident prevention regulations!

7.1 Installation

The pump is designed for stationary or transportable installa-
tion.

CAUTION! Danger of property damage!
Danger of damage due to incorrect handling.

Only suspend the pump by the strap with the aid or a
chain or rope, never by the electrical or float switch
cable or the pipe/hose connection.

The installation site or shaft for the pump must be free of frost.

The shaft must be cleared of coarse material such as rubble
before setting up and starting the pump.

The quality of the shaft must guarantee the unhindered mobil-
ity of the float switch.

Installation dimension / shaft dimensions (cf. 

FIG 2

), 

   

       

The diameter of the pressure pipe (pipe/hose connection)
should not be smaller than the pressure connection of the pipe
because of the increased risk of clogging and greater pressure
losses. To avoid pressure losses, it is recommended that the
pipe connection one number higher is selected.

Stationary wet sump installation 

In the case of a stationary wet sump installation of the pump
with a permanent pressure pipe, the pump must be positioned
and secured so that:

•The pressure pipe connection does not support the weight of

the pump.

•The load of the pressure pipe does not act on the connecting

socket.

•The pump is installed stress-free.

To protect against any backflow from the public drainage
pipe, the pressure pipe must be taken in an arc over the locally
established backflow level (usually street level). A non-return
valve does not represent a guaranteed backflow seal.

•The attached non-return valve should be installed if the pump

is installed permanently.

•Seal the pipe connections to the pressure port with Teflon

tape.

NOTE: Permanent leakage in this area can lead to
destruction of the non-return valve and of the screwed
connection.

Transportable wet sump installation

In the case of a transportable wet sump installation with hose
connection, the pump must be secured in the shaft to prevent
it from falling over and wandering (e.g. secure chain / rope
with slight pre-tension).

NOTE: When used in a sump without a firm base, the
pump must be put on a sufficiently large plate or hung
from a rope or a chain in a suitable position.

7.2 Electrical connection

Danger! Risk of fatal injury!
If the electrical connection is not made properly, there
is a risk of fatal injury from an electric shock.

Only allow the electrical connection to be made by an elec-
trician approved by the local electricity supplier and in
accordance with the local regulations in force.

•The type of mains connection current and voltage must corre-

spond to the details on the name plate

•Fuse in the power supply: 10 A, slow,

•Earth the installation according to the regulations.

•The installation of a leakage current protection switch to be

provided on site for a trip current of 30 mA is recommended
(caution when installing outside).

•The pump is ready to connect.

To connect the pump to the switchgear, the shock-proof plug
is disconnected and the connecting cable is then connected
as follows (see Installation and operating instructions for the
switchgear):

3-wire connection cable: 3x1.0 mm²

 

Socket and switchgear must be installed in a dry room and pro-
tected against flooding.

Pump

H

min

B

min

h ± 8

h1 ± 8

h2 ± 8

SUBSONS

[

mm

]

Premium 20

400

400 x 400

340

140

24

Premium 30

400

400 x 400

360

140

24

Pump

a

b

c

d

SUBSONS

[

mm

]

Premium 20

266

300

340

161

Premium 30

290

320

360

171

Conductor

Terminal

brown

L1

blue

N

green/yellow

PE

Summary of Contents for SUBSON Premium 20 MFP

Page 1: ...E EN SERVICE INSTALLATION AND OPERATING INSTRUCTIONS ISTRUZIONI DI MONTAGGIO USO E MANUTENZIONE INSTRUCCIONES DE INSTALACI N Y FUNCIONAMIENTO FRANCAIS ENGLISH ITALIANO ESPA OL N M S STOCK N 6 044 755...

Page 2: ...2...

Page 3: ...3...

Page 4: ...4 FIG 1 2 4 5 6 7 8 20 25 24 23 22 21 28 19 18 29 15 11 14 9 10 12 13 17 16 3 1 1 FIG 2 1 230V 50 Hz c b a d Bmin h 2 h 1 h H min...

Page 5: ...des consignes de s curit peut constituer un danger pour les personnes la pompe ou l installation Elle peut galement entra ner la suspension de tout recours en garantie Plus pr cis ment les dangers en...

Page 6: ...est interdit d utiliser la pompe pour vidanger les pisci nes tangs de jardin ou endroits similaires lorsqu il y a des personnes dans l eau AVERTISSEMENT Danger pour la sant Ne pas utiliser la pompe p...

Page 7: ...niveau d eau h FIG 2 et l arr te en cas de niveau d eau minimum h1 Les moteurs sont quip s d une protection moteur thermique qui arr te automatiquement le moteur en cas d chauffe ment excessif et l en...

Page 8: ...min localement souvent niveau de la rue Un clapet anti retour ne constitue pas un dis positif de retenue Dans le cas de l installation fixe de la pompe il est conseill d installer le clapet anti retou...

Page 9: ...refixer le c ble l aide du clip de maintien le plus pr s possible de l interrupteur dans le sens inverse au niveau de la poign e Le syst me automatique est ainsi teint et la pompe fonctionne en perman...

Page 10: ...cuve D monter la cr pine d aspiration rincer la cr pine d aspiration la roue sous l eau cou rante La pompe ne s enclenche pas ne s arr te pas L interrupteur flotteur est bloqu ou ne bouge pas libreme...

Page 11: ...current must be elimi nated Local directives or general directives e g IEC VDE etc and local power supply companies must be adhered to Risks through mechanical or bacteriological effects must be preve...

Page 12: ...to seal the oil chamber against the fluid The mechanical seal chamber is filled with medical white oil so that the mechanical seal is lubricated and cooled during a dry run A further rotary shaft sea...

Page 13: ...tion of the pump with a permanent pressure pipe the pump must be positioned and secured so that The pressure pipe connection does not support the weight of the pump The load of the pressure pipe does...

Page 14: ...elation to the handle and working in the opposite direction fix the cable as close to the switch as possible on the handle again with the aid of the clip The auto matic system is then switched off and...

Page 15: ...nnect the pump from the mains and remove from the shaft Remove the suction strainer and rinse the suc tion strainer impeller under running water Pump does not switch on off Float switch blocked or can...

Page 16: ...te le normative locali e generali ad esempio IEC ecc e le prescrizioni delle aziende elettriche locali 2 5 Prescrizioni di sicurezza per il montaggio e l ispezione Il gestore deve assicurare che le op...

Page 17: ...ssibili tubi flessibili ecc Accessori per montaggio sommerso fisso ad es valvole di intercettazione valvole di ritegno ecc 6 DESCRIZIONE E FUNZIONAMENTO 6 1 Descrizione della pompa FIG 1 Esempio SUBSO...

Page 18: ...materiali Pericolo di danneggiamento a causa di manipolazione impropria Agganciare la pompa solo all angolare di supporto con una catena oppure una fune non utilizzare mai a tal fine il cavo elettric...

Page 19: ...intervento punto di inserimento disinserimento pu essere modificato tramite il cavo del galleggiante libero spo stando il cavo all interno della molletta di fissaggio clip sull impugnatura della pompa...

Page 20: ...raffreddare la pompa riavvio auto matico Temperatura del fluido pompato troppo alta Lasciare raffreddare Pompa insabbiata oppure bloccata Staccare la pompa dalla rete e sollevarla fuori dal pozzetto S...

Page 21: ...la bomba o el sistema Fallos en los procedimientos obligatorios de mantenimiento y reparaci n Lesiones personales debidas a causas el ctricas mec nicas o bacteriol gicas Da os materiales 2 4 Instrucc...

Page 22: ...se al uso previsto es imprescindible observar las pre sentes instrucciones Todo uso que no figure en las mismas se considerar como no previsto 5 ESPECIFICACIONES DEL PRODUCTO 5 1 C digo 5 3 Suministro...

Page 23: ...eben ser reali zadas exclusivamente por personal especializado y de acuerdo con la normativa vigente Es imprescindible respetar en todo momento la normativa de prevenci n de accidentes 7 1 Instalaci n...

Page 24: ...da os mate riales El cierre mec nico no debe funcionar en seco La marcha en seco reduce la vida til del motor y del cierre mec nico Si el cierre mec nico ha sido da ado puede escaparse aceite en pequ...

Page 25: ...puede producir el ensuciamiento del l quido a consecuencia del escape de aceite de la c mara de aceite que est llena de aceite blanco medicinal S lo una empresa especializada o el servicio t cnico Sa...

Page 26: ...se enarena o se bloquea Desconecte la bomba de la red y s quela del pozo Desmonte el filtro de aspiraci n y lave el fil tro rodete con agua corriente La bomba no se conecta desco necta El interruptor...

Page 27: ...almson it W S L LEBANON Bou Khater building Mazda Center Jal El Dib Highway PO Box 90 281 Djeideh El Metn 1202 2030 Beiruth LEBANON TEL 961 4 722 280 FAX 961 4 722 285 wsl cyberia net lb SALMSON ARGEN...

Reviews: