1. General

These instructions, along with the general con-
ditions related to the pump, contain additional 
information regarding particular requirements for 
products in order to guarantee conforming use 
in potentially explosive areas in accordance with 
directive 2014/34/EU.

 1.1 Applications

The Nexis ATEX pumps can be used in gaseous 
atmospheres that require a product confor-
ming to group II, category 2G (use in zone 1 and 
zone 2), gas category IIB for a temperature class 
of T4.
The maximum temperature of the fluid must not 
exceed 90 °C.

2. Safety

These instructions contain additional informa- 

tion which must be observed when installing and 

starting the explosion-proof device. For this rea-

son, these operating instructions must, without 

fail, be read by the service technician and the 

responsible operator before installation and 

commissioning. The general instructions of this 

section and also the specific instructions men-

tioned in the following points must be observed.  

It is also essential to observe the general infor-
mation in the operating instructions.

 2.1 Instruction symbols in the installation  

instructions
Instruction symbols are similar to the pump  
installation and operating instructions.

 2.2 Staff training

The installation, operating and maintenance per-
sonnel must have the appropriate qualifications 
for this work.

 2.3 Danger in the event of non-observance of the 

safety instructions

Non-observance of the safety instructions can 

result in risk of injury to persons and damage 

the pump or installation. It may also result in a 

suspension of the warranty.

To be more precise, the dangers incurred can be 
as follows:

•  Failure of some major pump functions or of  

installation related to the risk of explosion.

 2.4 Safety instructions for the operator

The operator is in charge of the planning, instal-

lation and operating of the device in compliance 

with the provisions in force. National statutory 

provisions are to be complied with. In collabora-

tion with the competent authorities, the opera-

tor shall mark the potentially explosive areas and 

use the adequate materials. All information is 

included in the document related to explo- 
sion-proof protection.

  2.5  Safety advice for inspection and maintenance 

works

The operator must ensure that all inspection and 

installation work is carried out by authorised and 

qualified personnel, who are sufficiently infor-

med from their own detailed study of the ope-

rating instructions. Devices must not be opened 

in potentially explosive areas. All repair works 

have to be performed by the factory service 

department or departments authorised by the 

manufacturer.

In potentially explosive areas, the plastic parts 

must not be rubbed with a piece of rag or any 

similar material because of the risk of electro- 

static charging.

When carrying out maintenance and repair 

works, switch off the pump and ensure that the 

installation does not restart unexpectedly.

All maintenance work must be carried out wea-

ring suitable protective clothing (protective 

gloves) in order to prevent the risk of infection.

For safety reasons, maintenance work must only 

be carried out in the presence of another person 

and never in potentially explosive areas.

 2.6 Unauthorised modification and manufacture of 

spare parts
Alterations to the pump or installation may only 
be carried out with the manufacturer’s consent.  
The use of original spare parts and accessories 
authorised by the manufacturer will ensure  
safety.  
The use of any other parts may invalidate claims 
invoking the liability of the manufacturer for any 
consequences.

3. Operation in potentially explosive areas

Make sure that the temperature class of the 

material (see data mentioned on the rating plate) 
is appropriate for the operating space.

The water temperature must not exceed 90 °C 

and the ambient temperature must be kept bet-
ween -15 °C and +40 °C.

Do not cover the pump in order to allow good 

motor ventilation and try to limit the amount of 
dust.

Always respect the maintenance and repair 
recommendations for the motor and the pump.

Respect the installation and commissioning in- 

structions (filling, flushing out...) in order to eli-

minate any risk of dry running and operation at 

zero delivery rate.

The delivery rate controller supplied with the 

ATEX pump controls the presence of water in the 

upper part of the pump. The electrical connec-

tion must allow the motor to be switched off in 
case of a lack of water.

Summary of Contents for Nexis first V ATEX

Page 1: ...ERVICE INSTALLATION AND STARTING INSTRUCTIONS INSTALACI N Y INSTRUCCIONES DE PUESTA EN MARCHA INSTALLAZIONE E MESSA IN SERVIZIO FRAN AIS ENGLISH ESPA OL ITALIANO N M S STOCK N 4213807 ed02 1710 Nexis...

Page 2: ...Fig 1 1 2 5 3 4 6 7...

Page 3: ...fr Notice de montage et de mise en service 4 en Installation and operating instructions 7 es Instrucciones de instalaci n y funcionamiento 10 it Istruzioni di montaggio uso e manutenzione 13...

Page 4: ...ec les autorit s comp tentes il doit proc der au mar quage des zones pr sentant un risque d explo sion et employer le mat riel ad quat Ces infor mations sont reprises dans le document relatif la prote...

Page 5: ...ATEX 2 raccords Ruban t flon Notices de mise en service 4 2 Principe de fonctionnement du contr leur Bas sur les principes thermodynamiques le capteur de d bit est chauff une temp rature l g rement s...

Page 6: ...u bout de la temporisation r gl e 6 Pi ces de rechange Toutes les pi ces de rechange doivent tre com mand es directement aupr s du service apr s vente Salmson Afin d viter des erreurs veuillez sp cifi...

Page 7: ...information is included in the document related to explo sion proof protection 2 5 Safety advice for inspection and maintenance works The operator must ensure that all inspection and installation wor...

Page 8: ...TEX delivery rate sensor 2 connections Teflon band Commissioning manual 4 2 Operating principle of the controller Based on thermodynamic principles the delivery rate sensor is heated to a temperature...

Page 9: ...the rating plate data for orders The spare parts catalogue is available at www salmson com 7 Safe disposal Proper disposal and recycling of this product prevents damage to the environment and risks to...

Page 10: ...s En colaboraci n con las autoridades competentes el operador debe marcar las reas con riesgo de explosi n y utilizar los materiales adecuados Toda la informaci n necesaria est incluida en el document...

Page 11: ...Sensor de caudal 4 Caja fuera del rea peligrosa 5 Monitor de caudal 6 Man metro 7 V lvula de conexi n de impulsi n 4 1 Suministro Bomba multietapas vertical Monitor de caudal sensor de caudal ATEX 2...

Page 12: ...mson com 7 Eliminaci n segura La correcta eliminaci n y el reciclado de este producto evita da os en el medio ambiente y posibles peligros para la salud Seg n las normativas para eliminar el producto...

Page 13: ...rtate nel documento relativo alla protezione antideflagrazione 2 5 Istruzioni di sicurezza per i lavori di ispezione e manutenzione L utente tenuto a fare eseguire le operazioni di ispezione e install...

Page 14: ...ATEX 2 raccordi Nastro in Teflon Manuale di messa in servizio 4 2 Principio di funzionamento del monitor di controllo del flusso I base ai principi della termodinamica il sensore di portata viene risc...

Page 15: ...odotto da ordinare Il catalogo delle parti di ricambio disponibile su www salmson com 7 Smaltimento sicuro Il corretto smaltimento e riciclaggio di questo prodotto previene danni all ambiente e rischi...

Page 16: ...s suivantes und entsprechender nationaler Gesetzgebung _ Maschinenrichtlinie 2006 42 EG _ Machinery 2006 42 EC _ Machines 2006 42 CE und gem ss Anhang 1 1 5 1 werden die Schutzziele der Niederspannung...

Page 17: ...a Wilo Salmson France SAS ndearbha onn an cur s os ar na t irg at i r iteas seo siad i gcomhr ir leis na for lacha at sna treoracha seo a leanas na hEorpa agus leis na dl the n isi nta is infheidhme o...

Page 18: ...lo Salmson France SAS izjavlja da so izdelki navedeni v tej izjavi v skladu z dolo ili naslednjih evropskih direktiv in z nacionalnimi zakonodajami ki jih vsebujejo Wilo Salmson France SAS declara que...

Page 19: ......

Page 20: ...D USER AND MUST BE LEFT ON SITE This product was manufactured on a site certified ISO 14 001 respectful of the environment This product is composed of materials in very great part which can be recycle...

Reviews: