Light Commercial R410A on-off 
 

S13-01.01.13en

 

4. Features

 

4.1 High quality coils: 

The coil is constructed of advanced inner grooved copper tube and aluminum fins. 

4.2 Anti-rust, 500 hours salt spray test. 

4.3 Low operation sound level: Well-known stable and quiet running fan motor. 

4.4 Well-known compressor. 

4.5 Compact design: Smaller dimension and larger stuffing capacity. 

4.6 Universal outdoor unit design. 

4.7 R410A environment friendly refrigerant. 

General Information 
 

Summary of Contents for SIB-100BAY

Page 1: ...S13 01 01 13en Light Commercial Air Conditioner R410A ON OFF Service Manual 2013 ...

Page 2: ...13en Part 1 General Information 2 Part 2 Indoor Units 8 Part 3 Outdoor Units 82 Part 4 Installation 106 The specifications designs and information in this book are subject to change without notice for product improvement General Information 1 ...

Page 3: ...cial R410A on off S13 01 01 13en Part 1 General Information 1 Model Names of Indoor Outdoor Units 3 2 External Appearance 4 2 1 Indoor Units 4 2 2 Outdoor Units 5 3 Nomenclature 6 4 Features 7 General Information 2 ...

Page 4: ...Matched indoor units Heat Pump SOB 50VA SIB 50BAV SOB 60VA SOB 100YA SANYO SOB 140YA SANYO SOB 200YA SANYO SOB 250YA SANYO SIB 250DAY Type Function 50 60 100 140 200 250 Four way cassette compact Cooling and heating Four way cassette Cooling and heating Ceiling floor Cooling and heating SIB 60BAV SIB 60TAV SIB 60DAV SIB 100BAY SIB 100TAY SIB 100DAY SIB 140BAY SIB 140TAY SIB 140DAY SIB 200BAY SIB 2...

Page 5: ...Light Commercial R410A on off S13 01 01 13en 2 External Appearance 2 1 Indoor Units General Information 4 Four way Cassette Four way Cassette Compact Ceiling Floor High Static Pressure Duct ...

Page 6: ...Light Commercial R410A on off S13 01 01 13en 2 2 Outdoor Units General Information 5 ...

Page 7: ...phase 50 Hz Y 3 phases 50 Hz Refrigerant A R410A Capacity 50 5 2kWt 60 7 0kWt 100 10 5kWt 140 14 0kWt 200 17 6kWt 250 28 0Wt Series B Business Product category BA Cassette type TA High static pressure duct DA Ceiling Floor type Manufacturer s brand S akata General Information 6 Unit I Indoor O Outdoor ...

Page 8: ...per tube and aluminum fins 4 2 Anti rust 500 hours salt spray test 4 3 Low operation sound level Well known stable and quiet running fan motor 4 4 Well known compressor 4 5 Compact design Smaller dimension and larger stuffing capacity 4 6 Universal outdoor unit design 4 7 R410A environment friendly refrigerant General Information 7 ...

Page 9: ...Light Commercial R410A on off S13 01 01 13en Part 2 Indoor Units Four way Cassette Type Compact 9 Four way Cassette Type 21 Ceiling Floor Type 41 HSP Duct Type 63 Indoor Units 8 ...

Page 10: ... 2 Specifications 11 3 Dimensions 12 4 Service Space 13 5 Capacity tables 14 6 Wiring Diagrams 15 7 Air Velocity and Temperature Distributions 16 8 Electric Characteristics 17 9 Sound Levels 18 10 The Specification of Power 19 11 Field Wiring 20 Indoor Units Four way Cassette Type Compact 9 ...

Page 11: ...ribution to the heat exchange uniform 4 Improvement for easy installation and maintenance Little space is required for installation into a shallow ceiling Because of the compactness and weight reduction of the main unit and panel all models can be installed without a hoist 5 Inside E box design The E box is simply and safely build inside the indoor unit of witch ceiling side is 600mm 600mm It is c...

Page 12: ...6 Input W 1881 COP 3 19 Indoor fan motor Model YDK37 4P Qty 1 Input W 80 65 46 Capacitor uF 2UF 400 450V Speed Hi Mi Lo r min 1000 875 710 Indoor coil Number of rows 2 Tube pitch a row pitch b mm 21 13 37 Fin spacing mm 1 3 Fin type code Hydrophilic aluminum Tube outside dia and type mm 7Inner grooved copper tube Coil length height width mm 1370 210 26 74 Number of circuits 4 Indoor air flow Hi Mi...

Page 13: ...Light Commercial R410A on off S13 01 01 13en 3 Dimensions SIB 50BAV Indoor Units Four way Cassette Type Compact 12 ...

Page 14: ...Light Commercial R410A on off S13 01 01 13en 4 Service Space Indoor Units Four way Cassette Type Compact 13 ...

Page 15: ... 57 2 81 2 60 Input kW 2 00 1 98 1 73 1 61 1 57 1 38 1 34 Cooling OUTDOOR TEMPERATURE DRY Indoor Conditions 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC 21ºC D 15ºC W Total capacity kW 4 91 4 86 4 81 4 72 3 77 3 54 Sensitive capacity kW 3 92 3 89 3 85 3 77 3 02 2 83 Input kW 5 29 5 26 5 22 5 11 5 27 5 47 24ºC D 17ºC W Total capacity kW 5 02 4 97 4 92 4 82 3 86 3 62 Sensitive capacity kW 4 01 3 97 3 94 3 86 3 09 ...

Page 16: ...Light Commercial R410A on off S13 01 01 13en 6 Wiring Diagrams SIB 50BAV Indoor Units Four way Cassette Type Compact 15 ...

Page 17: ...Light Commercial R410A on off S13 01 01 13en 7 Air Velocity and Temperature Distributions Temperature Indoor Units Four way Cassette Type Compact 16 Airflowvelocity ...

Page 18: ...R410A on off S13 01 01 13en 8 Electric Characteristics Supply Remark MFA Max Fuse Amps A Indoor Units Four way Cassette Type Compact 17 Model Indoor Units Power Hz Voltage Min Max MFA SIB 50BAV 50 220 240V 198V 254V 25 ...

Page 19: ...Light Commercial R410A on off S13 01 01 13en 9 Sound Levels Indoor Units Four way Cassette Type Compact 18 Model Noise level dB A H M L SIB 50BAV 44 41 38 FOUR WAY CASSETTE TYPE 1 0m Microphone ...

Page 20: ...ype Compact 19 Type SIB 50BAV Power Phase 1 phase Frequency and Voltage 220 240V 50Hz Circuit Breaker Fuse A 40 25 Indoor Unit Power Wiring mm2 3 2 5 Indoor Outdoor Connecting Wiring Ground wire mm2 2 5 Outdoor Unit Power Wiring Strong Electric Signal 5 2 5 Weak Electric Signal mm2 2 core shield wire 2 0 75 ...

Page 21: ...Light Commercial R410A on off S13 01 01 13en 11 Field Wiring SIB 50BAV Indoor Units Four way Cassette Type Compact 20 ...

Page 22: ...2 Specifications 25 3 Dimensions 27 4 Service Space 28 5 Capacity tables 29 6 Wiring Diagrams 33 7 Air Velocity and Temperature Distributions 35 8 Electric Characteristics 36 9 Sound Levels 37 10 The Specification of Power 38 11 Field Wiring 39 Indoor Units Four way Cassette Type 21 ...

Page 23: ...t airflow volume guarantees the excellent capacity 4 The adoption of the most advanced 3 Dimensional Screw fan Reduces the air resistance passing through Smoothes the air flow Makes air speed distribution to the heat exchange uniform 5 Fresh air makes life healthier and more comfortable 6 Drainage pump can take up the condenser water to 750mm 7 Ultra thin machine body to easy installation and main...

Page 24: ...esign around the panel preventing the distortion for the panel 10 New outlet frame design to make the phenomena of coagulation great improvement prevent the condensing water from damaging the air guide strip 11 Adding rib on the panel of fan outlet which can avoid the air outlet direct flow to people 12 Adding digital tube displaying on the display board LED can display the Error Code to make the ...

Page 25: ...eight up to 30m refer to 15 Optimal design smaller Control Box Space saving and convenient for wiring Using fire resistance galvanized steel for E box material Metal box make the control part more stable and prevent damaging 16 360 air flow panel 360 air flow delivery ensures uniform airflow distribution Indoor Units Four way Cassette Type 24 ...

Page 26: ... 143 116 100 Capacitor uF 3uF 450V 3 5uF 450V Speed Hi Mi Lo r min 800 550 400 770 640 550 Indoor coil Number of rows 2 2 Tube pitch a row pitch b mm 21 13 37 21 13 37 Fin spacing mm 1 5 1 5 Fin type code Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type mm 7 Inner grooved copper tube 7 Inner grooved copper Coil length height width mm 1990 168 26 74 1990 168 26 74 Number of circu...

Page 27: ...citor uF 3 5uF 450V 4UF 450V Speed Hi Mi Lo r min 770 640 550 840 640 550 Indoor coil Number of rows 2 3 Tube pitch a row pitch b mm 21 13 37 21 13 37 Fin spacing mm 1 5 1 5 Fin type code Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type mm 7 Inner grooved copper tube 7 Inner grooved copper Coil length height width mm 1990 252 26 74 2080x252x40 11 Number of circuits 12 12 Indoor ...

Page 28: ...imensions SIB 60BAV 4 install hanger Gas side Liquid side E parts box Pump inspect hole Drain hole SIB 100BAY SIB 140BAY SIB 200BAY 4 install hanger Gas side Liquid side E parts box Pump inspect hole Drain hole Indoor Units Four way Cassette Type 27 ...

Page 29: ...ation and maintenance The ceiling is horizontal and its structure can endure the weight of the indoor unit The outlet and the inlet are not impeded and the influence of external air is the least The air flow can reach throughout the room The connecting pipe and drainpipe could be extracted out easily There is no direct radiation from heaters Indoor Units Four way Cassette Type 28 ...

Page 30: ... 5 32 Input 2 87 2 43 2 14 1 97 1 85 27ºC TC 8 97 7 14 5 78 5 62 5 02 Input 3 04 2 62 2 31 2 14 1 99 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 7 53 7 31 6 96 6 60 6 32 SC 5 49 5 41 5 36 5 28 5 31 Input 1 98 2 05 2 23 2 33 2 40 24 17ºC DB WB TC 7 74 7 53 7 17 6 82 6 39 SC 5 73 5 64 5 59 5 52 5 37 Input 2 10 2 18 2 33 2 43 2 55 27 19ºC DB WB TC 7 88...

Page 31: ...12 8 40 Input 4 80 4 07 3 58 3 30 3 09 27ºC TC 14 16 11 28 9 12 8 88 7 92 Input 5 09 4 40 3 87 3 58 3 34 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 11 13 10 82 10 29 9 77 9 35 SC 8 12 8 00 7 92 7 81 7 85 Input 3 17 3 29 3 57 3 73 3 85 24 17ºC DB WB TC 11 45 11 13 10 61 10 08 9 45 SC 8 47 8 35 8 27 8 16 7 94 Input 3 37 3 49 3 73 3 89 4 09 27 19ºC DB...

Page 32: ...put 6 58 5 58 4 91 4 52 4 24 27ºC TC 17 70 14 10 11 40 11 10 9 90 Input 6 97 6 02 5 30 4 91 4 57 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 14 48 14 07 13 39 12 70 12 16 SC 10 57 10 41 10 31 10 16 10 21 Input 4 28 4 45 4 82 5 03 5 20 24 17ºC DB WB TC 14 89 14 48 13 80 13 11 12 29 SC 11 02 10 86 10 76 10 62 10 33 Input 4 55 4 71 5 03 5 25 5 52 27 19...

Page 33: ...put 6 99 5 92 5 21 4 80 4 50 27ºC TC 20 77 16 54 13 38 13 02 11 62 Input 7 40 6 39 5 62 5 21 4 86 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 16 96 16 48 15 68 14 88 14 24 SC 12 38 12 20 12 07 11 90 11 96 Input 4 90 5 09 5 52 5 76 5 95 24 17ºC DB WB TC 17 44 16 96 16 16 15 36 14 40 SC 12 91 12 72 12 60 12 44 12 10 Input 5 21 5 39 5 76 6 01 6 31 27 1...

Page 34: ...Light Commercial R410A on off S13 01 01 13en 6 Wiring Diagrams 6 1 SIB 60BAV Indoor Units Four way Cassette Type 33 ...

Page 35: ...Light Commercial R410A on off S13 01 01 13en 6 2 SIB 100BAY SIB 140BAY 6 3 SIB 200BAY Indoor Units Four way Cassette Type 34 ...

Page 36: ...Light Commercial R410A on off S13 01 01 13en 7 Air Velocity and Temperature Distributions Temperature Indoor Units Four way Cassette Type 35 Airflowvelocity ...

Page 37: ...tics Remark MFA Max Fuse Amps A Indoor Units Four way Cassette Type 36 Model Indoor Units Power Supply Hz Voltage Min Max MFA SIB 60BAV 50 220 240V 198V 254V 25 SIB 100BAY 50 380 415V 342V 418V 15 SIB 140BAY 50 380 415V 342V 418V 15 SIB 200BAY 50 380 415V 342V 418V 25 ...

Page 38: ... on off S13 01 01 13en 9 Sound Levels Indoor Units Four way Cassette Type 37 Model Noise level dB A H M L SIB 60BAV 42 40 39 SIB 100BAY 44 42 41 SIB 140BAY 44 42 41 SIB 200BAY 47 44 43 FOUR WAY CASSETTE TYPE 1 0m Microphone ...

Page 39: ...wer Phase 1 phase 3 phase 3 phase Frequency and Voltage 220 240V 50Hz 380 415V 50Hz 380 415V 50Hz Circuit Breaker Fuse A 40 25 25 15 40 25 Indoor Unit Power Wiring mm2 3 2 5 5 2 5 5 2 5 Indoor Outdoor Connecting Wiring mm2 Ground Wiring 4 0 2 5 2 5 Outdoor Unit Power Wiring 3 2 5 5 2 5 5 2 5 Strong Electric Signal 3 2 5 3 1 0 3 2 5 Weak Electric Signal 2 core shield wire 2 0 75 ...

Page 40: ...Light Commercial R410A on off S13 01 01 13en 11 Field Wiring Wiring chart SIB 60BAV Indoor Units Four way Cassette Type 39 ...

Page 41: ...Light Commercial R410A on off S13 01 01 13en SIB 100BAY SIB 140BAY SIB 200BAY Indoor Units Four way Cassette Type 40 ...

Page 42: ...42 2 Specifications 43 3 Dimensions 46 4 Service Space 47 5 Capacity tables 48 6 Wiring Diagrams 53 7 Air Velocity and Temperature Distributions 55 8 Electric Characteristics 57 9 Sound Levels 58 10 The Specification of Power 59 11 Field Wiring 60 Indoor Units Ceiling Floor 41 ...

Page 43: ...rectional control minimizes the air resistance and produces wilder air flow to vertical direction The range of horizontal air discharge is widened which secures wider air flow distribution to provide more comfortable air circulation no matter where the unit is set up 1 4 Three level fan speed more humanism design meets different air supply requirement 1 5 Water proof by utilizing the absorbing pla...

Page 44: ...an motor Model YSK55 4L YSK55 4L Qty 1 1 Input W 125 105 85 125 105 85 Capacitor uF 2 5uF 450V 2 5uF 450V Speed Hi Mi Lo r min 1310 1190 1040 1310 1190 1040 Indoor coil Number of rows 2 3 Tube pitch a row pitch b mm 25 4 22 21 13 37 Fin spacing mm 1 3 1 3 Fin type code Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type mm 7 Inner grooved copper tube 7 Inner grooved copper tube Coi...

Page 45: ...YSK59 4D 4 Qty 1 2 Input W 159 142 130 102 98 96 Capacitor uF 3 5uF 450V 2 5uF 450V Speed Hi Mi Lo r min 1290 1170 1060 1230 1130 1070 Indoor coil Number of rows 3 3 Tube pitch a row pitch b mm 21 13 37 25 4 22 Fin spacing mm 1 3 1 5 Fin type code Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type mm Φ7 Inner grooved copper tube φ9 5 Inner grooved copper tube Coil length height wi...

Page 46: ... 72 Heating Indoor fan motor Model YSK59 4D Qty 2 Input W 89 5 81 5 77 5 Capacitor uF 2 5uF 450V Speed Hi Mi Lo r min 1170 1070 995 Indoor coil Number of rows 3 Tube pitch a row pitch b mm 25 4 22 Fin spacing mm 1 7 Fin type code Hydrophilic aluminum Tube outside dia and type mm φ9 5 Inner grooved copper tube Coil length height width mm 1360 254 66 Number of circuits 5 Indoor air flow Hi Mi Lo m3 ...

Page 47: ...n 3 Dimensions a Wall mounting installation b Ceiling installation Indoor Units Ceiling Floor 46 Capacity Btu h A B C D E F G 18000 24000 990 660 203 505 506 907 200 36000 1280 660 203 795 506 1195 200 48000 60000 1670 680 240 1070 450 1542 200 ...

Page 48: ...Light Commercial R410A on off S13 01 01 13en 4 Service Space Indoor Units Ceiling Floor 47 ...

Page 49: ... Input 2 20 1 86 1 64 1 51 1 42 27ºC TC 7 08 5 64 4 56 4 44 3 96 Input 2 33 2 01 1 77 1 64 1 53 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 5 62 5 46 5 19 4 93 4 72 SC 4 10 4 04 4 00 3 94 3 96 Input 1 38 1 43 1 55 1 62 1 67 24 17ºC DB WB TC 5 78 5 62 5 35 5 09 4 77 SC 4 27 4 21 4 18 4 12 4 01 Input 1 47 1 52 1 62 1 69 1 78 27 19ºC DB WB TC 5 88 5 72...

Page 50: ...5 78 5 32 Input 2 85 2 42 2 13 1 96 1 84 27ºC TC 8 97 7 14 5 78 5 62 5 02 Input 3 02 2 61 2 29 2 13 1 98 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 7 53 7 31 6 96 6 60 6 32 SC 5 49 5 41 5 36 5 28 5 31 Input 1 94 2 01 2 18 2 28 2 35 24 17ºC DB WB TC 7 74 7 53 7 17 6 82 6 39 SC 5 73 5 64 5 59 5 52 5 37 Input 2 06 2 13 2 28 2 37 2 50 27 19ºC DB WB TC ...

Page 51: ... 40 Input 4 75 4 03 3 55 3 26 3 06 27ºC TC 14 16 11 28 9 12 8 88 7 92 Input 5 04 4 35 3 83 3 55 3 30 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 11 13 10 82 10 29 9 77 9 35 SC 8 12 8 00 7 92 7 81 7 85 Input 3 45 3 57 3 88 4 05 4 18 24 17ºC DB WB TC 11 45 11 13 10 61 10 08 9 45 SC 8 47 8 35 8 27 8 16 7 94 Input 3 66 3 79 4 05 4 22 4 44 27 19ºC DB WB ...

Page 52: ...5 94 5 03 4 43 4 08 3 83 27ºC TC 17 70 14 10 11 40 11 10 9 90 Input 6 29 5 44 4 78 4 43 4 13 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 14 84 14 42 13 72 13 02 12 46 SC 10 83 10 67 10 56 10 42 10 47 Input 4 15 4 31 4 67 4 88 5 03 24 17ºC DB WB TC 15 26 14 84 14 14 13 44 12 60 SC 11 29 11 13 11 03 10 89 10 58 Input 4 41 4 57 4 88 5 09 5 35 27 19ºC D...

Page 53: ... 37 6 25 5 50 5 06 4 75 27ºC TC 22 42 17 86 14 44 14 06 12 54 Input 7 81 6 75 5 93 5 50 5 12 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 16 96 16 48 15 68 14 88 14 24 SC 12 38 12 20 12 07 11 90 11 96 Input 5 25 5 45 5 91 6 17 6 37 24 17ºC DB WB TC 17 44 16 96 16 16 15 36 14 40 SC 12 91 12 72 12 60 12 44 12 10 Input 5 58 5 77 6 17 6 43 6 76 27 19ºC D...

Page 54: ...Light Commercial R410A on off S13 01 01 13en 6 Wiring Diagrams SIB 50TAV SIB 60TAV Indoor Units Ceiling Floor 53 ...

Page 55: ...Light Commercial R410A on off S13 01 01 13en SIB 100TAY SIB 140TAY SIB 200TAY Indoor Units Ceiling Floor 54 ...

Page 56: ...Light Commercial R410A on off S13 01 01 13en 7 Air Velocity and Temperature Discharge angle 60 CEILING Airflow velocity Distributions Temperature Indoor Units Ceiling Floor 55 ...

Page 57: ...Light Commercial R410A on off S13 01 01 13en Discharge angle 60 FLOOR Temperature Airflow velocity Indoor Units Ceiling Floor 56 ...

Page 58: ...FA Max Fuse Amps A Indoor Units Ceiling Floor 57 Model Indoor Units Power Supply Hz Voltage Min Max MFA SIB 50TAV 50 220 240V 198V 254V 16 SIB 60TAV 50 220 240V 198V 254V 25 SIB 100TAY 50 380 415V 342V 418V 20 SIB 140TAY 50 380 415V 342V 418V 20 SIB 200TAY 50 380 415V 342V 418V 20 ...

Page 59: ...al R410A on off S13 01 01 13en 9 Sound Levels Ceiling Floor Indoor Units Ceiling Floor 58 Model Noise level dB A H M L SIB 50TAV 43 41 38 SIB 60TAV 45 43 40 SIB 100TAY 45 43 40 SIB 140TAY 50 47 45 SIB 200TAY 50 49 47 ...

Page 60: ... 60000Btu h Power Phase 1 phase 1 phase 3 phase Frequency and Voltage 220 240V 50Hz 220 240V 50Hz 380 415V 50Hz Circuit Breaker Fuse A 20 16 40 25 40 20 Indoor Unit Power Wiring mm2 3 2 5 3 2 5 5 2 5 Indoor Outdoor Connecting Ground Wiring 2 5 2 5 2 5 Outdoor Unit Power Wiring 3 2 5 5 2 5 Strong Electric Signal 5 2 5 3 2 5 3 1 0 Weak Electric Signal 2 core shield wire 2 core shield mm2 ...

Page 61: ...ration in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation When wiring please choose the corresponding chart or it may cause damage The signs of the I J indoor terminal block in the some of following fugures may be replaced by L N L1 N1 Indoor Units Ceiling Floor 60 ...

Page 62: ...Light Commercial R410A on off S13 01 01 13en SIB 50TAV SIB 60TAV Indoor Units Ceiling Floor 61 ...

Page 63: ...Light Commercial R410A on off S13 01 01 13en SIB 100TAY SIB 140TAY SIB 200TAY Indoor Units Ceiling Floor 62 ...

Page 64: ...ct Type 1 Features 64 2 Specifications 65 3 Dimensions 67 4 Service Space 69 5 Wiring Diagrams 70 6 Capacity Tables 72 7 Static Pressure 76 8 Electric Characteristics 77 9 Sound Levels 78 10 The Specification of Power 79 11 Field Wiring 80 Indoor Units HSP Duct Type 63 ...

Page 65: ...y Wired control and group control are available High capacity of cooling heating efficient and energy saving Innovative air supply which provides homogeneous conditioning of the room temperature It can be used in office hospital commercial place and home the air conditioner will create the comfortable and elegance environment for you Compact design Smaller dimension and larger stuffing capacity Un...

Page 66: ...r Model YDK200 4F YDK200 4F Qty 1 1 Input W 500 460 345 500 460 345 Capacitor uF V 15uF 370 450V 15uF 370 450V Speed Hi Mid Lo r min 1060 980 820 1060 980 820 Indoor coil Number of rows 3 3 Tube pitch a row pitch b mm 25 4 x22 25 4 x22 Fin spacing mm 1 6 1 6 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside diameter and type mm Φ9 5 inner grooved tube Φ9 5 inner grooved tube Coil l...

Page 67: ...l YDK360 4F YSK400 4C Qty 1 1 Input W 630 570 435 930 740 592 Capacitor uF V 15uF 370 450V 15uF 370 450V Speed Hi Mid Lo r min 1210 1135 960 1080 920 790 Indoor coil Number of rows 4 3 Tube pitch a row pitch b mm 25 4x22 25 4 x22 Fin spacing mm 1 6 1 6 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside diameter and type mm Φ9 5 inner groove tube Φ9 5 inner grooved tube Coil length h...

Page 68: ...Light Commercial R410A on off S13 01 01 13en 3 Dimensions Indoor Units HSP Duct Type 67 ...

Page 69: ...Light Commercial R410A on off S13 01 01 13en Indoor Units HSP Duct Type 68 ...

Page 70: ...Light Commercial R410A on off S13 01 01 13en 4 Service Space Ensure enough space required for installation and maintenance Indoor Units HSP Duct Type 69 ...

Page 71: ...Light Commercial R410A on off S13 01 01 13en 5 Wiring Diagrams 5 1 SIB 60DAV 5 2 SIB 100DAY Indoor Units HSP Duct Type 70 ...

Page 72: ...Light Commercial R410A on off S13 01 01 13en 5 3 SIB 140DAY SIB 200DAY Indoor Units HSP Duct Type 71 ...

Page 73: ...0 6 16 5 78 5 32 Input 2 78 2 35 2 07 1 91 1 79 27ºC TC 8 97 7 14 5 78 5 62 5 02 Input 2 94 2 54 2 24 2 07 1 93 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 7 53 7 31 6 96 6 60 6 32 SC 5 49 5 41 5 36 5 28 5 31 Input 2 00 2 08 2 25 2 35 2 43 24 17ºC DB WB TC 7 74 7 53 7 17 6 82 6 39 SC 5 73 5 64 5 59 5 52 5 37 Input 2 13 2 20 2 35 2 45 2 58 27 19ºC DB...

Page 74: ...0 Input 4 64 3 93 3 46 3 19 2 99 27ºC TC 14 16 11 28 9 12 8 88 7 92 Input 4 92 4 25 3 74 3 46 3 23 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 11 13 10 82 10 29 9 77 9 35 SC 8 12 8 00 7 92 7 81 7 85 Input 3 19 3 31 3 59 3 75 3 87 24 17ºC DB WB TC 11 45 11 13 10 61 10 08 9 45 SC 8 47 8 35 8 27 8 16 7 94 Input 3 39 3 51 3 75 3 91 4 11 27 19ºC DB WB TC...

Page 75: ...90 5 00 4 40 4 05 3 80 27ºC TC 17 70 14 10 11 40 11 10 9 90 Input 6 25 5 40 4 75 4 40 4 10 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 14 84 14 42 13 72 13 02 12 46 SC 10 83 10 67 10 56 10 42 10 47 Input 4 26 4 42 4 79 5 00 5 16 24 17ºC DB WB TC 15 26 14 84 14 14 13 44 12 60 SC 11 29 11 13 11 03 10 89 10 58 Input 4 52 4 68 5 00 5 22 5 48 27 19ºC DB ...

Page 76: ...2 6 38 5 61 5 16 4 85 27ºC TC 22 42 17 86 14 44 14 06 12 54 Input 7 97 6 89 6 06 5 61 5 23 Cooling Outdoor conditions DB Indoor Conditions kW 18ºC 21ºC 28ºC 35ºC 43ºC 21 15ºC DB WB TC 16 96 16 48 15 68 14 88 14 24 SC 12 38 12 20 12 07 11 90 11 96 Input 4 87 5 05 5 48 5 72 5 90 24 17ºC DB WB TC 17 44 16 96 16 16 15 36 14 40 SC 12 91 12 72 12 60 12 44 12 10 Input 5 17 5 35 5 72 5 96 6 27 27 19ºC DB ...

Page 77: ...ressure 24 M KODEL 24 MODEL 36 Pa 190 170 150 130 110 100 90 70 50 30 10 900 1000 1100 1200 1300 1400 1500 Air volume m3 h 1600 1700 1800 MODEL 48 MODEL 60 Indoor Units HSP Duct Type 76 External static pressure Pa High speed Mid speed Low speed Slight speed ...

Page 78: ...teristics Remark MFA Max Fuse Amps A Indoor Units HSP Duct Type 77 Model Indoor Units Power Supply Hz Voltage Min Max MFA SIB 60DAV 50 220 240V 198V 254V 15 SIB 100DAY 50 380 415V 342V 418V 25 SIB 140DAY 50 380 420V 342V 440V 25 SIB 200DAY 50 380 420V 342V 440V 25 ...

Page 79: ...S13 01 01 13en 9 Sound Levels Indoor Units HSP Duct Type 78 Model Noise level dB A H M L SIB 60DAV 46 45 44 SIB 100DAY 56 54 50 SIB 140DAY 58 56 51 SIB 200DAY 57 53 50 Concealed Duct Type Discharge Suction Duct Duct 1 4m Microphone ...

Page 80: ...hase 3 phase Frequency and Voltage 220 240V 50Hz 380 415V 50Hz Circuit Breaker Fuse A 30 15 40 25 Indoor Unit Power Wiring mm2 3x2 5 5x2 5 Indoor Outdoor Connecting Wiring mm2 Ground Wiring Outdoor Unit Power Wiring 3x2 5 5x2 5 Strong Electric Signal 3 core cable 3x1 5 3 core cable 3x2 5 Weak Electric Signal 2 core shielded wire 2x0 75 ...

Page 81: ...Light Commercial R410A on off S13 01 01 13en 11 Field Wiring SIB 60DAV Indoor Units HSP Duct Type 80 ...

Page 82: ...Light Commercial R410A on off S13 01 01 13en SIB 100DAY SIB 140DAY SIB 200DAY Indoor Units HSP Duct Type 81 ...

Page 83: ...01 01 13en Part 3 Outdoor Units Specifications 83 1 2 Dimensions 85 3 Service Space 87 4 Piping Diagrams 88 5 Wiring Diagrams 90 6 Electric Characteristics 93 7 Operation Limits 94 8 Sound Levels 95 9 Troubleshooting 96 Outdoor Units 82 ...

Page 84: ... Capacitor μF 50μF 440V 450V 50μF 440V 450V Refrigerant oil ml ESTER OIL VG74 750 ESTER OIL VG74 950 Outdoor fan motor Model YDK48 6H A YDK100 6D Qty 1 1 Input W 110 168 7 Capacitor μF 3μF 450V 5μF 450V Speed r min 890 900 Outdoor coil Number of rows 2 2 Tube pitch a row pitch b mm 21x13 37 21x13 37 Fin spacing mm 1 4 1 4 Fin type Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type...

Page 85: ...l YDK190 6D B YDK65 6 YDK65 6F YDK65 6 YDK65 6F Qty 1 2 2 Input W 290 148 156 148 140 Capacitor μF 10μF 450V 3 5UF 450V 2 3 5μF 450V 2 Speed r min 830 800 800 Outdoor coil Number of rows 2 2 2 Tube pitch a row pitch b mm 21x13 37 21 13 37 22 19 05 Fin spacing mm 1 4 1 4 1 6 Fin type Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Tube outside dia and type mm φ7 Inner grooved copper ...

Page 86: ...t Commercial R410A on off S13 01 01 13en 2 Dimensions mm Outdoor Units 85 Model A B C D E F H SOB 50VA 762 530 290 315 270 282 593 SOB 60VA 842 560 335 360 312 324 695 SOB 100YA 990 624 366 396 340 354 966 ...

Page 87: ...Light Commercial R410A on off S13 01 01 13en mm Outdoor Units 86 Model A B C D E F H SOB 140YA 900 590 378 400 330 340 1167 SOB 200YA 900 590 378 400 330 340 1167 ...

Page 88: ...mmercial R410A on off S13 01 01 13en 3 Service Space Wall or obstacle More than 30cm Air inlet More than 60cm More than 30cm Maintain channel Air inlet More than 60cm Air outlet More than 200cm Outdoor Units 87 ...

Page 89: ...Y VALVE 3 WAY VALVE ACCUMULATOR COOLING HEATING COMPRESSOR For SOB 50VA SOB 60VA the accumulator is not included SOB 140YA INDOOR OUTDOOR CHECK VALVE Heating Model only LIQUID SIDE 2 WAY VALVE T3 Condenser sensor CAPILIARY TUBE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER T4 Ambient temp T2 Evaporator temp sens GAS SIDE 4 WA 3 WAY VALVE ACCUMULATOR COOLING HEATING COMPRESSOR Outdoor Units 88 s...

Page 90: ...UID SIDE 2 WAY VALVE T3 Condenser sensor CAPILIARY TUBE HEAT EXCHANGE EVAPORATOR HEAT EXCHANGE CONDENSER T4 Ambient temp T2 Evaporator temp sensor GAS SIDE 3 WAY VALVE Compressor Oil separator COOLING HEATING Oil return Capillary Outdoor Units 89 Accumulator T3 temp sensor 4 WAY VALVE T1 Room temp sensor ...

Page 91: ...Light Commercial R410A on off S13 01 01 13en 5 Wiring Diagrams SOB 50VA Outdoor Units 90 ...

Page 92: ...Light Commercial R410A on off S13 01 01 13en SOB 60VA SOB 100YA Outdoor Units 91 ...

Page 93: ...Light Commercial R410A on off S13 01 01 13en SOB 140YA SOB 200YA Outdoor Units 92 ...

Page 94: ...3en 6 Electric Characteristics Outdoor Units 93 Model Outdoor Unit Hz Voltage Min Max SOB 50VA 50 220 240V 198V 254V SOB 60VA 50 220 240V 198V 254V SOB 100YA 50 380 415V 342V 418V SOB 140YA 50 380 415V 342V 418V SOB 200YA 50 380 415V 342V 418V ...

Page 95: ...g 43 24 21 5 17 30 17 30 Indoor temperature WB Indoor temperature DB Outdoor Units 94 Outdoor temperature DB Outdoor temperature WB Standard operation Standard operation Operation mode Outdoor temperature Room temperature Cooling operation 21 43 17 30 Heating operation 5 24 17 30 ...

Page 96: ...18000Btu h 48000Btu h 60000Btu h Outdoor Unit 1 0m Note H 0 5 height of outdoor unit Note The point A is in the middle of the whole outdoor panel Outdoor Units 95 Model Noise level dB A SOB 50VA 54 SOB 60VA 55 SOB 100YA 57 SOB 140YA 59 SOB 200YA 59 Microphone H ...

Page 97: ...Light Commercial R410A on off S13 01 01 13en 9 Troubleshooting 9 1 Self diagnosis Indoor unit s LED indication 1 For Big Four way cassette Outdoor Units Troubleshooting 96 ...

Page 98: ... 2 For A5 Duct 3 For AHU indoor unit The LED on indoor PCB 4 For CONSOLE Outdoor Units Troubleshooting 97 Type Contents LED1 LED2 LED3 ERROR Pipe Temp sensor error Quick flash Off Off ERROR Wire controller input error Quick flash Off Quick flash ...

Page 99: ...Type Contents LED Flashing Remark 1 Normal Standing by Operation lamp flashes at Nothing wrong with the unit when LED indicate these contents 2 Normal System Off All lamps are off 3 Normal System startup Operation lamp on 4 Normal Forced cooling Operation lamp flashes at 5 Protection Over current protection of the compressor occurs 4 times in 1h Lamps of operation timer defrosting only fan flashin...

Page 100: ...mp sensor Replace indoor PCB b Evaporator temperature sensor is abnormal Evaporator temperature sensor is abnormal No Whether the resistance of the evaporator temp sensor is 10K Replace evaporator temp sensor Yes Replace indoor PCB c Condenser temperature sensor is abnormal Condenser temperature sensor is abnormal No Replace condenser temp sensor Whether the resistance of the condenser temp sensor...

Page 101: ... of the communication line s red and black end between the indoor and outdoor unit is 5V Yes Check the indoor unit main board CN5 or replace the main control board Yes Replace indoor PCB e EEPROM malfunction EEPROM malfunction Yes EEPROM chip is broken Replace EEPROM No Yes Replace 9177 chip Check whether the main control chip 9177 is broken No Check PCB board or replace the main control board Out...

Page 102: ...ll Yes Yes Check whether the water level switch is broken Replace the water level switch No No Replace the water pump Check whether the water pump is normal Yes Check PCB board or replace the main control board g Temperature sensor error of water pump E5 No Whether the resistance of the temp sensor is 10K Replace temp sensor Yes Replace indoor PCB Outdoor Units Troubleshooting 101 ...

Page 103: ... current normally Is the current in rated range No Yes Possible reason The outdoor PCB is defective 1 2 3 4 5 Outdoor fan is defective The compressor is defective Refrigerant is over charged Air enter the refrigerant system Heat exchanger is too dirty c Lack of phase Lack of phase Check the power supply is it 3 phase 380 415V Yes Check the connection between power supply and terminal is the voltag...

Page 104: ...unit is bad ventilation Refrigerant is leakage K1 switch is defective 1 2 3 4 The wires is loose to K2 Air or other gas in the refrigerant Heat exchanger is dirty Outdoor fan or fan blade is defective Outdoor unit is bad ventilation Refrigerant is two much K2 switch is defective 5 6 7 5 6 7 e Open circuit and short circuit trouble of T3 Is connection to connector of temp sensor good No Yes Repair ...

Page 105: ...eplace the sensor Indoor PCB is defective g High temperature protection of condenser High temperature protection of condenser Check the resistance of the temp sensor according to Annex 1 is it normal No Yes Replace the sensor Possible reason 1 2 3 Air or other gas in the refrigerant Heat exchanger is dirty Outdoor fan or fan blade is defective Outdoor unit is bad ventilation Refrigerant is leakage...

Page 106: ...15 0 41164 4 44 0000 36 6 13059 76 1 34105 116 0 40060 3 41 5878 37 5 87359 77 1 29078 117 0 38991 2 39 8239 38 5 62961 78 1 25423 118 0 37956 1 37 1988 39 5 39689 79 1 21330 119 0 36954 0 35 2024 40 5 17519 80 1 17393 120 0 35982 1 33 3269 41 4 96392 81 1 13604 121 0 35042 2 31 5635 42 4 76253 82 1 09958 122 0 3413 3 29 9058 43 4 57050 83 1 06448 123 0 33246 4 28 3459 44 4 38736 84 1 03069 124 0 ...

Page 107: ...3 01 01 13en Part 4 Installation 1 Precaution on Installation 107 2 Vacuum Dry and Leakage Checking 108 3 Additional Refrigerant Charge 110 4 Water Drainage 111 5 Insulation Work 114 6 Wiring 116 7 Test Operation 117 Installation 106 ...

Page 108: ...epair points Locate The Pipe Drill a hole in the wall suitable just for the size of the wall conduit then set on the fittings such as the wall conduit and its cover Bind the connecting pipe and the cables together tightly with binding tapes Do not let air in which will cause water leakage by condensation Pass the bound connecting pipe through the wall conduit from outside Be careful of the pipe al...

Page 109: ...ronment common vacuum dry special vacuum dry Common vacuum dry procedure Vacuum dry for the first time connect the all purpose detector to the inlet of liquid pipe and gas pipe and run the vacuum pump more than two hours the vacuum pump should be below 755mmHg If the pump can t achieve below 755mmHg after pumping 2 hours moisture or leakage point will still exist in the pipe At this time it should...

Page 110: ...ime Fill nitrogen to 0 5Kgf cm2 Because nitrogen is for drying gas it has vacuum drying effect during vacuum destroy But if the moisture is too much this method can t dry thoroughly So please pay more attention to prevent water entering and forming condensation water Vacuum dry for the second time 1h pumping Determinant Pass if achieving below 755mmHg If 755mmHg can t be achieved in 2h repeat proc...

Page 111: ...accidents so always ensure that the appropriate refrigerant is charged Refrigerant containers shall be opened slowly Always use protective gloves and protect your eyes when charging refrigerant The outdoor unit is factory charged with refrigerant Calculate the added diameter and the length of the liquid side pipe of the outdoor unit indoor unit refrigerant according to the Remark R g Additional re...

Page 112: ...or unit After powering on there is some water in water receiver plate Please check if the drain pump can operate correctly All connection should be firm Wipe color on PVC pipe to note connection Climbing horizontal and bending conditions are prohibited The dimension of drainpipe can t less than the connecting dimension of indoor drainpipe Heat insulation should be done well to prevent condensation...

Page 113: ...age without drain pump After finishing drainpipe installation pour some water into the water receiver plate to check if the water flows smoothly 4 5 2 Drainage with drain pump Poke the Water Level Switch remove the cover use water pipe to pour 2000ml water into the water receipt plate through the water inlet Turn on the power to Cooling operation Check the pump s operation and switch on the Water ...

Page 114: ...amp flashes even overflow from the water receipt plate Keep on pouring water until it gives an alarm signal for high water level check if the pump drains water at once If the water level can t fall below the alarmed water level after 3 minutes the air conditioner will stop Turn off the power and drain the remained water and then turn on the air conditioner Note the drain stuff in the main water re...

Page 115: ... expanding area and the flange area should be heat insulated 5 2 2 Insulation for non jointing parts and non connection parts For construction convenience before laying pipes use insulation material to insulate the pipes to be deal with at the same time at two ends of the pipe remain some length not to be insulated in order to be welded and check the leakage after laying the pipes 5 2 3 Insulate f...

Page 116: ... 5 4 1 The jointing area expanding area and the flange area should be heat insulated after passing the pressure test 5 4 2 The gas and liquid pipe should be heat insulated individually the connecting part should be heat insulated individually 5 4 3 Use the attached heat insulation material to insulate the pipe connections pipes tie in expand nut of the indoor unit Installation 116 ...

Page 117: ...Light Commercial R410A on off S13 01 01 13en 6 Wiring Please refer to the Wiring Diagram Installation 117 ...

Page 118: ...tioner is pre heated by turning on the power 3 According to the user s requirement install the remote controller when the remote controller s signal can reach the indoor unit smoothly 4 Test operation Set the air conditioner under the mode of COOLING with the remote controller and check the following points Indoor unit Whether the switch on the remote controller works well Whether the buttons on t...