10-048
TROUBLESHOOTING
2-6-12. Water spray indicator lamp does not light
• Check that water spray pump can be activated.
Reference Fig. : 2-6-4
Check point
Check/Cause
Action
1. Harness
• Measure resistance between water spray switch terminal
2 wire LW and combination meter connector terminal wire
No. 29 wire LW.
Standard resistance : 10
Ω
or less
• If resistance is NG, harness is faulty.
Repair or replace
harness.
2. Combination Meter
(Water spray indicator
lamp)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 15 inlet wire Y and ground
terminal wire B.
• Starter switch terminal wire No. 14 inlet wire BrB and
ground terminal wire B.
Standard voltage : 12 V or more
(2) When starter switch is ON and water spray switch is
ON, measure voltage between combination meter water
spray terminal wire No. 29 inlet wire LW and chassis
ground.
Standard voltage : 12 V or more
• If above items (1) and (2) are OK and water spray
indicator lamp does not light, combination meter is faulty.
Replace combination
meter.
2-6-13. Liquid spray indicator lamp does not light (TW types)
• Check that liquid spray pump can be activated.
Reference Fig. : 2-6-4
Check point
Check/Cause
Action
1. Harness
• Measure resistance between liquid spray switch terminal
2 wire BrW and combination meter connector terminal
wire No. 88 wire BrW.
Standard resistance : 10
Ω
or less
• If resistance is NG, harness is faulty.
Repair or replace
harness.
2. Combination Meter
(Liquid spray indicator
lamp)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 15 inlet wire Y and ground
terminal wire B.
• Starter switch terminal wire No. 14 inlet wire BrB and
ground terminal wire B.
Standard voltage : 12 V or more
(2) When starter switch is ON and liquid spray switch is
ON, measure voltage between combination meter liquid
spray terminal wire No. 88 inlet wire BrW and chassis
ground.
Standard voltage : 12 V or more
• If above items (1) and (2) are OK and liquid spray
indicator lamp does not light, combination meter is faulty.
Replace combination
meter.
10̲TROUBLESHOOTING̲oku.indd 10-048
10̲TROUBLESHOOTING̲oku.indd 10-048
2012/11/14 20:25:58
2012/11/14 20:25:58
Summary of Contents for SW300-1
Page 14: ...01 SAFETY P001 010 indd 2 01 SAFETY P001 010 indd 2 2012 11 20 8 18 16 2012 11 20 8 18 16...
Page 22: ...01 SAFETY P001 010 indd 10 01 SAFETY P001 010 indd 10 2012 11 20 8 18 17 2012 11 20 8 18 17...
Page 102: ...06 VIBRATORY DRUM indb 2 06 VIBRATORY DRUM indb 2 2012 11 20 8 26 03 2012 11 20 8 26 03...
Page 112: ...06 VIBRATORY DRUM indb 12 06 VIBRATORY DRUM indb 12 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 114: ...06 VIBRATORY DRUM indb 14 06 VIBRATORY DRUM indb 14 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 149: ...BRAKE 07 BRAKE P000 002 indd 7 07 BRAKE P000 002 indd 7 2012 10 05 9 39 43 2012 10 05 9 39 43...
Page 156: ...08 SPRAY SYSTEMS indb 2 08 SPRAY SYSTEMS indb 2 2012 10 17 10 41 15 2012 10 17 10 41 15...
Page 158: ...08 SPRAY SYSTEMS indb 4 08 SPRAY SYSTEMS indb 4 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 160: ...08 SPRAY SYSTEMS indb 6 08 SPRAY SYSTEMS indb 6 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 162: ...08 SPRAY SYSTEMS indb 8 08 SPRAY SYSTEMS indb 8 2012 10 17 10 41 16 2012 10 17 10 41 16...