10-059
TROUBLESHOOTING
3-3-2. Vibrator frequency is too low
Check point
Cause
Check/Action
1. Oil Level of
Hydraulic Oil Tank
Oil level in hydraulic oil tank is low.
Fill tank until correct oil level is obtained.
2. Vibrator Circuit
Pressure
Circuit does not obtain required pressure
because setting pressure of relief valve is
low.
• Measure vibrator circuit pressure.
• If low, check relief valve or replace it if
necessary.
3. Suction Filter for
Vibrator Pump
Flow rate of vibrator pump decreases as
well as charge pressure decreases due to
clogged
fi
lter.
Clean suction
fi
lter or replace it if necessary.
4. Vibrator Motor
Decrease in vibrator motor rpm due to
internal leakage in vibrator motor.
• Measure drain quantity from vibrator motor.
• If drain quantity is larger than standard
value, repair vibrator motor or replace it if
necessary.
5. Vibrator Pump
Insuf
fi
cient discharge rate from vibrator
pump due to reduced ef
fi
ciency of vibrator
pump.
• Measure discharge
fl
ow rate of vibrator
pump with
fl
ow meter.
• If discharge
fl
ow rate is not within speci
fi
ed
range, repair vibrator pump or replace it if
necessary.
Insuf
fi
cient pump discharge due to wear of
vibrator pump drive shaft spline.
Replace vibrator pump.
3-3-3. Vibrator does not stop
Check point
Cause
Check/Action
1. Vibrator Solenoid
Valve
Vibrator solenoid does not return to
vibration mode select switch “O” (OFF)
position.
Repair vibrator solenoid valve or replace it if
necessary.
3-3-4. Vibrator system is overheating
Check point
Cause
Check/Action
1. Oil Level of
Hydraulic Oil Tank
Oil level in hydraulic oil tank is low.
Fill tank until correct oil level is obtained.
2. Vibrator Circuit
Pressure
If load is excessively heavy, relief valve
opens, causing temperature of hydraulic oil
in circuit to rise.
• Measure vibrator circuit pressure.
• If high, decrease vibration load.
3. Suction Filter for
Vibrator Pump
Load of vibrator pump increases due to
clogged
fi
lter, causing temperature of
hydraulic oil in circuit to rise.
Clean suction
fi
lter or replace it if necessary.
10̲TROUBLESHOOTING̲oku.indd 10-059
10̲TROUBLESHOOTING̲oku.indd 10-059
2012/11/14 20:25:58
2012/11/14 20:25:58
Summary of Contents for SW300-1
Page 14: ...01 SAFETY P001 010 indd 2 01 SAFETY P001 010 indd 2 2012 11 20 8 18 16 2012 11 20 8 18 16...
Page 22: ...01 SAFETY P001 010 indd 10 01 SAFETY P001 010 indd 10 2012 11 20 8 18 17 2012 11 20 8 18 17...
Page 102: ...06 VIBRATORY DRUM indb 2 06 VIBRATORY DRUM indb 2 2012 11 20 8 26 03 2012 11 20 8 26 03...
Page 112: ...06 VIBRATORY DRUM indb 12 06 VIBRATORY DRUM indb 12 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 114: ...06 VIBRATORY DRUM indb 14 06 VIBRATORY DRUM indb 14 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 149: ...BRAKE 07 BRAKE P000 002 indd 7 07 BRAKE P000 002 indd 7 2012 10 05 9 39 43 2012 10 05 9 39 43...
Page 156: ...08 SPRAY SYSTEMS indb 2 08 SPRAY SYSTEMS indb 2 2012 10 17 10 41 15 2012 10 17 10 41 15...
Page 158: ...08 SPRAY SYSTEMS indb 4 08 SPRAY SYSTEMS indb 4 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 160: ...08 SPRAY SYSTEMS indb 6 08 SPRAY SYSTEMS indb 6 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 162: ...08 SPRAY SYSTEMS indb 8 08 SPRAY SYSTEMS indb 8 2012 10 17 10 41 16 2012 10 17 10 41 16...