10-052
TROUBLESHOOTING
2-6-15 Horn does not sound
Reference Fig. : 2-6-5
Check point
Check/Cause
Action
1. Horn
• Disconnect horn and directly connect battery positive
terminal to horn terminal wire Lg side and negative
terminal to horn terminal wire B side.
• If horn does not sound, horn is faulty.
Replace horn.
2. Horn Relay
(1) When starter switch is ON and horn switch is pressed,
measure voltage between horn relay terminal 2 outlet
wire LgW and chassis ground.
Standard voltage : 12 V or more
(2) When starter switch is ON and horn switch is pressed,
measure voltage between horn relay terminal 5 outlet
wire Lg and chassis ground.
Standard voltage : 12 V or more
• If above item (1) is OK and item (2) is NG, horn relay is
faulty.
Replace horn relay.
3. Horn Switch
• When horn switch is not pressed, measure resistance
between horn switch terminals.
Standard resistance : 100 k
Ω
or more
• If resistance is abnormal, horn switch is faulty.
Replace horn switch.
4. Harness Connecting
Between Terminals
• Measure resistance of harness connecting between
terminals.
Standard resistance : 10
Ω
or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
2-6-16. Backup buzzer does not sound
Reference Fig. : 2-6-5
Check point
Check/Cause
Action
1. Backup Buzzer
• Disconnect backup buzzer and directly connect battery
positive terminal to backup buzzer terminal wire BY side
and negative terminal to backup buzzer terminal wire B
side.
• If backup buzzer does not sound, backup buzzer is faulty.
Replace backup buzzer.
2. Backup Buzzer Switch (1) When starter switch is ON, measure voltage between
backup buzzer switch terminal COM inlet wire RG and
chassis ground.
Standard voltage : 12 V or more
(2) When starter switch is ON and F-R lever is in “R”,
measure voltage between backup buzzer switch
terminal NO outlet wire BY and chassis ground.
Standard voltage : 12 V or more
• If above item (1) is OK and item (2) is NG, backup buzzer
switch is faulty.
Replace backup buzzer
switch.
3. Harness Connecting
Between Terminals
• Measure resistance of harness connecting between
terminals.
Standard resistance : 10
Ω
or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
10̲TROUBLESHOOTING̲oku.indd 10-052
10̲TROUBLESHOOTING̲oku.indd 10-052
2012/11/14 20:25:58
2012/11/14 20:25:58
Summary of Contents for SW300-1
Page 14: ...01 SAFETY P001 010 indd 2 01 SAFETY P001 010 indd 2 2012 11 20 8 18 16 2012 11 20 8 18 16...
Page 22: ...01 SAFETY P001 010 indd 10 01 SAFETY P001 010 indd 10 2012 11 20 8 18 17 2012 11 20 8 18 17...
Page 102: ...06 VIBRATORY DRUM indb 2 06 VIBRATORY DRUM indb 2 2012 11 20 8 26 03 2012 11 20 8 26 03...
Page 112: ...06 VIBRATORY DRUM indb 12 06 VIBRATORY DRUM indb 12 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 114: ...06 VIBRATORY DRUM indb 14 06 VIBRATORY DRUM indb 14 2012 11 20 8 26 04 2012 11 20 8 26 04...
Page 149: ...BRAKE 07 BRAKE P000 002 indd 7 07 BRAKE P000 002 indd 7 2012 10 05 9 39 43 2012 10 05 9 39 43...
Page 156: ...08 SPRAY SYSTEMS indb 2 08 SPRAY SYSTEMS indb 2 2012 10 17 10 41 15 2012 10 17 10 41 15...
Page 158: ...08 SPRAY SYSTEMS indb 4 08 SPRAY SYSTEMS indb 4 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 160: ...08 SPRAY SYSTEMS indb 6 08 SPRAY SYSTEMS indb 6 2012 10 17 10 41 16 2012 10 17 10 41 16...
Page 162: ...08 SPRAY SYSTEMS indb 8 08 SPRAY SYSTEMS indb 8 2012 10 17 10 41 16 2012 10 17 10 41 16...