9-051
TROUBLESHOOTING
3-2-1. Machine moves neither forward nor backward 2/2
Check point
Cause
Check/Action
11. Rear Axle
Sticking of disc brakes causes brakes to
remain applied.
Replace disc brakes.
12. Flange
Drive torque is not transmitted to pump due
to faulty flange.
Replace flange.
3-2-2. Machine moves in one direction only (forward or backward)
Check point
Cause
Check/Action
1. F-R Lever Linkage F-R lever linkage is faulty.
Check and adjust F-R lever linkage or
replace it if necessary.
2. High Pressure
Relief Valve
Low circuit pressure due to incorrect high
pressure relief setting or internal leakage of
high pressure relief valve.
Interchange two high pressure relief
valves.
If faulty condition is accordingly reversed,
inspect high pressure relief valve or
replace it if necessary.
•
•
3-2-3. Slow machine speed or small drive force 1/2
Check point
Cause
Check/Action
1. Bypass Valve
Bypass valve is slightly open.
Close bypass valve completely.
2. F-R Lever Linkage F-R lever linkage is faulty.
Check and adjust F-R lever linkage or
replace it if necessary.
3. Charge Circuit
Pressure
Stroke of propulsion pump swash plate
is small because charge pressure is low,
decreasing discharge rate of propulsion
pump.
Measure charge pressure.
If low, check and adjust charge relief valve
or replace it if necessary.
•
•
Insufficient charge pump discharge.
Repair charge pump or replace it if
necessary.
Charge pressure decreases due to internal
leakage of solenoid valve connecting oil
supply circuit with charge circuit.
Parking brake solenoid valve
•
When solenoid is energized, check if oil
flows in return circuit to tank.
If oil is flowing, repair solenoid valve or
replace it if necessary.
•
•
4. Hydraulic Oil Filter
Flow rate of charge pump decreases as
well as charge pressure decreases due to
clogged filter.
Clean hydraulic oil filter or replace it if
necessary.
5. Propulsion Motor
Propulsion motor inlet pressure is low.
Measure propulsion motor inlet pressure.
If low, inspect high pressure relief valve or
replace it if necessary.
•
•
Propulsion circuit pressure is not held in
propulsion motor case.
If pressure in propulsion motor case is not
within allowable range, repair propulsion
motor or replace it if necessary.
Output of propulsion motor decreases and
number of revolutions decreases due to
internal leakage of propulsion motor.
Measure drain quantity from propulsion
motor.
If drain quantity is larger than standard
value, repair propulsion motor or replace it
if necessary.
•
•
Summary of Contents for SV201-1
Page 1: ...SV201 1 SHOP MANUAL 3498 64064 0...
Page 2: ......
Page 4: ......
Page 12: ......
Page 13: ...SAFETY...
Page 14: ......
Page 22: ......
Page 23: ...SPECIFICATIONS...
Page 24: ......
Page 25: ......
Page 38: ......
Page 39: ...ENGINE AND CONTROLS...
Page 40: ......
Page 41: ......
Page 48: ......
Page 49: ...HYDRAULIC SYSTEMS...
Page 50: ......
Page 51: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 60: ......
Page 62: ......
Page 64: ......
Page 65: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 84: ......
Page 86: ......
Page 87: ...ELECTRICAL SYSTEM...
Page 88: ......
Page 90: ......
Page 92: ......
Page 94: ......
Page 97: ...VIBRATORY DRUM REAR AXLE...
Page 98: ......
Page 106: ......
Page 138: ......
Page 144: ......
Page 145: ...BRAKE...
Page 146: ......
Page 148: ......
Page 150: ......
Page 153: ...INSPECTION AND ADJUSTMENT...
Page 154: ......
Page 174: ......
Page 175: ...TROUBLESHOOTING...
Page 176: ......
Page 187: ......