3.
PERIODICAL MAINTENANCE
0
Control link
Remove the operator seat floor cover and the cover
under the dashoboard.
Check the bolts and nuts for looseness. Adjust the rod.
Liquid spray strainer
Take off the liquid tank cover. Take out and clean the
strainer, change the strainer if necessary.
Li
uid tank cover
Strainer
(5) Every 1000 operating hours
Suction filter
Take off the hydraulic tank cover. Take out and clean the
strainer, change the strainer if necessary.
Hydraulic tank
1) Remove the drain plug and drain the oil while it is
warm.
2) After cleaning the inside of the tank, fill the tank to the
specified level with new hydraulic fluid.
3) Start and run the engine at idling for 2 - 5 minutes.
When air bubbles have disappeared from the oil, stop
the engine and check the oil level again.
A
WARNING
When draining a hot oil, be careful not to get burned.
—
62 —