28
OwnersManual-TileSaw-CTC705-Rev11-2023
CTC705 Brush Locations
c. Disconnect the power source from the CTC705
d. There are two (2) brushes in the CTC705 motor, one (1) on each side. Always replace both
brushes.
e. Use a coin or wide blade screwdriver to remove the Carbon Brush Cap. Use care not to
damage the Carbon Brush Cap.
i. Inspect the Carbon Brush Cap for damage. If the Cap has any signs of damage replace
with 70184683359 BRUSH CAP (1) 705 NOTE: Brush Caps are sold individually.
4. Remove the Carbon Brush from the Brush Holder.
5. Remove the second brush following steps 3 and 4
6. Use low pressure compressed air to blow out the motor and brush holders. Motor while
blowing out the motor. This will help clean any debris from inside of the motor.
7. Place the new Carbon Brush into one of the holders.
8. Replace the Brush Cap. Do not over tighten.
9. Repeat steps 7 and 8 for the remaining Carbon Brush
10. Connect the CTC705 to a 115v/60 Hz/1 Phase power source and test run.
a. If the machine does not start this is a sign that the Carbon Brush was not installed
properly or was damaged during installation, repeat steps 1 to 10 again.
b. No power
c. Power switch in the OFF position
d. After checking 10a to 10c and the unit still does not run see a Norton Clipper Service
center or your selling distributor for service.
Brush
Cap
and
Carbon
Brush
Brush
Cap
and
Carbon
Brush
Located
On
Back
of
Motor
SAW MAINTENANCE &
TROUBLE SHOOTING