VERS. 2017.06.12
CM 401_MAN_EN
13
Machine
Model / code
Measured value of vibration
emission at m/s
2
Uncertainty K
m/s
2
Tool used
Model / code
CM 401 500
30.1.230V
70184626981
CM 401 500
40.3.400V
70184626983
CM 401 600
30.1.230V
70184626994
CM 401 600
40.3.400V
70184627004
CM 401 500
30.1.115V
70184627497
CM 401 600
30.1.115V
70184627498
<2.5
0.5
Clipper ZDH500
diamond blade
The vibration value is lower and does not exceed 2.5 m / s.
Values determined using the procedure described in the standard
EN 12418.
The measurements are made with new machines. Actual values may vary with site conditions, in
terms of:
Materials worked
Wear Machine
Lack of maintenance
Inappropriate tool for application
Tool in poor condition
Unskilled operator
Etc…
The exposure time to vibration is based on the performance of work (related to the adequacy
Machine / Tool / worked material / operator)
When evaluating risks due to hand-arm vibration, you need to take into account effective usage at
rated power of machine during a full day of work; quite often you will realise that effective utilisation
time represents around 50% of overall duration of work. You have to consider, of course, breaks,
water feeding, preparation of work, time to move the machine, disk mounting…
2.6 Statement regarding noise emission
Summary of Contents for Norton Clipper CM 401 Series
Page 1: ...CM 401 OPERATING INSTRUCTIONS Translation of the original instructions...
Page 2: ...VERS 2017 06 12 CM 401_MAN_EN 2...
Page 25: ...VERS 2017 06 12 CM 401_MAN_EN 25 7 3 Circuit diagram 230V Motor...
Page 26: ...VERS 2017 06 12 CM 401_MAN_EN 26 115V Motor...
Page 27: ...VERS 2017 06 12 CM 401_MAN_EN 27 400V Motor CM 401 3kW 4 1 A...