Code
Name
Description 1
Check Posltion
Description 2
Connector (B323S01)
P4
Connector (B268S01)
P16
- Check Slave board
Slave board
6SP505AMWB268S01
- Check master board
Master board
6SP505AMWB323S01
- Check connector and wiring between
master board and cooler
CONNECTOR (B323S01)
P4 (B323S01) -- TS3 (RS485)
- Check board of cooler
Indoor board
B296D / B296A
- Check master boad
Master board
6SP505AMWB323S01
- Check all connector sensor on contor board
at position
Slave board
P3 (B268S01)
- Check the wire of the sensor
-
-
- Check sensor resistance
-
-
- Check operation of the control board
Control board
6SP505AMWB313SS01
- Check all connector sensor on control board
at position
Slave board
P3 (B268S01)
- Check the wire of the sensor
-
-
- Check sensor resistance
-
-
- Check operation of the control board
Control board
6SP505AMWB313SS01
- Check all connector sensor on control board
at position
Slave board
P3 (B268S01)
- Check the wire of the sensor
-
-
- Check sensor resistance
-
-
- Check operation of the control board
Control board
6SP505AMWB313SS01
- Check all connector sensor on control board
at postion
Slave board
-
- Check the wire of the sensor
Room sensor
6SP551A-00013
- Check sensor resistance
-
-
- Check operation of the control board
Control board
6SP505AMWB313SS01
- Check all connector sensor on control board
at position
Slave board
P6 (B268S01)
- Check the wire of sensor
-
-
- Check sensor resistance
-
-
- Check operation of the control board
Slave board
6SP505AMWB268S01
- Check all connector sensor on control board
at position
Slave board
P7 (B268S01)
- Check the wire of sensor
-
-
- Check sensor resistance
-
-
- Check operation of the control board
BOARD SLAVE
6SP505AMWB268S01
- Check the wiring between compressor 1
and control board of comoressor
-
-
- Check the coil resistance of the compressor
1
-
-
- Check operation of the compressor 1
control board
Control board 1
6SP505AMWB313SS01
- Check the wiring between compressor 2
and control board of comoressor
-
-
- Check the coil resistance of the compressor
2
-
-
- Check operation of the compressor 2
control board
Control board 2
6SP505AMWB313SS01
21
-
-
-
-
-
22
-
-
-
-
-
23-29
-
-
-
-
-
- Check the quantity of working fiuld in the
system
-
-
- Check blockage of refrigerant piping
-
-
- Check the cooling of the heat sink
- Check operation of compressor 1
Compressor 1 ANB78FVAMT
6SP200S-3510002
- Check resistance of sensor at compressor
1 outlet
Sensor Discharge 1
-
- Check reading sensor of slave board
Slave board
6SP505AMWB268S01
- Check the quantity of working fiuld in the
system
-
-
- Check blockage of refrigerant piping
-
-
- Check the cooling of the heat sink
-
-
- Check operation of compressor 2
Compressor 2 ANB78FVAMT
6SP200S-3510002
- Check resistance of sensor at compressor
2 outlet
Sensor Discharge 2
-
- Check reading sensor of slave board
Slave board
6SP505AMWB268S01
Saijo denki International co.,ltd.
60
12
Communication loss with
Indoor unit
There is not communicate
wilt cooler.
13
Outdoor unit Ambient
Temperature sensor fail
There is an error in the
temper sensor at the heat
sink Inlet.
ERROR CODE
16
Outdoor unit Mid Coil
Temperature sensor fail
There is an error in the
refrigerant temperatre
sensor at a middle of heat
sink coil.
17
Compressor1 Discharge
pipe temperature sensor
fail
Threr is an error in the
refrigerant temperature
sensor at compressor 1
outlet.
Control Ass'y
11
Communication loss with
Slave PCB
There is not communicate
wilt Slave PCB.
- Check connector and wiring between
master board and slave board
14
Outdoor unit Inlet Coil
Temperature sensor fail
There is an error in the
refrigerant temperature
sensor at the heat sink coil
Inlet.
15
Outdoor unit Outlet Coil
Temperature sensor fail
There is an error in the
refrigerant temperature
sensor at the heat sink coil
Outlet.
20
Compressor2 Current
sensor fail
There is an error in the
dldctric current sensor of
compressor 2
30
Compressor1 Discharge
pipe over temperature
The Outlet temperature of
copressor 1 is overheated.
18
Compressor2 Discharge
pipe temperature sensor
fail
Threr is an error in the
refrigerant temperature
sensor at compressor 2
outlet.
19
Compressor1 Current
sensor fail
There is an error in the
dldctric current sensor of
compressor 1
31
Compressor2 Discharge
pipe over temperature
The Outlet temperature of
copressor 2 is overheated.
6SP501ASRV029