Code
Name
Description 1
Check Posltion
Description 2
SCV-13-A-VTGP1
SCV-20-A-VTGP1
SCV-25-A-VTGP1
SCV-30-A-VTGP1
SCV-36-A-VTGP1
SCV-50-A-VTGP1
SCV-60-A-VTGP1
01
-
-
-
-
-
-
-
-
-
-
- Check blockage at the drain pipe
-
-
-
-
-
-
-
- Check operating of the water pump
-
- Check operation of the float
-
6SP505AMWB296DS01
- Check all connector sensor on control
board all position P1
- Check the wire of the sensor
- Check sensor resistance
- Check operation of the control board
Control board
6SP505AMWB296DS01
- Check all connector sensor on control
board all position P2
- Check the wire of the sensor
- Check sensor resistance
- Check operation of the control board
Control board
6SP505AMWB296DS01
- Check all connector sensor on control
board all position P3
- Check the wire of the sensor
- Check sensor resistance
- Check operation of the control board
Control board
6SP505AMWB296DS01
- Check connector motor on control board
- Check operation of motor
Fan motor
- Check operation of the control board
Control board
6SP505AMWB296DS01
Fan coil ass'y
6SP301ASCD019V
Cross flow fan
6SP431J-0000702
6SP431J-0000702
6SP431J-0000702
6SP431J-0000702
6SP431J-0000702
6SP431J-0000702
6SP431J-0000702
- Check speed of fan motor
Fan motor
- Check the quantity of working fluid in the
system
08
-
-
-
-
-
-
-
-
-
09
-
-
-
-
-
-
-
-
-
10
-
-
-
-
-
-
-
-
-
Saijo denki International co.,ltd.
54
ERROR CODE
There is an error in the cooling
motor of the Indoor unit.
6SP505AMWB296DS02
-
-
Control Ass'y
- Check operation of the control board
6SP505AMWB338HA
6SP505AMWB296DS03
02
Indoor unit Flood Protection
Control board
6SP454A-00008
6SP454B-00010
6SP505AMWB296DS02
There is an error in the drainage
of the indoor unit
03
05
Indoor unit Inlet Temperature
sensor fail
There is an error in the
refrigerant temperature sensor at
the Evaporator inlet.
Indoor unit Outlet Temperature
sensor fail
There is an error in the
refrigerant temperature sensor at
the Evaporator outlet.
04
Indoor unit Room Temperature
sensor fail
There is an error in room
temperature seneor at the indoor
unit.
6SP505AMWB296DS02
6SP505AMWB296DS03
6SP505AMWB296DS03
6SP551A-00025
6SP504CSHA031
Defrost sensorR (105 cm.)
(Outlet)
07
-
-
06
6SP505AMWB296DS02
6SP505AMWB296DS03
6SP511A-00090
6SP511A-00090
6SP301ASCD015V
6SP301ASCE009V
6SP301ASCF007V
Indoor Antifreeze protection
There is freezing at cooling coil.
- Check the coil and fan blades
Indoor unit Motor fail
6SP551A-00005
6SP505AMWB296DS02
6SP505AMWB296DS03
-
Defrost sensor (60 cm.)
(Inlet)
Room thermistor