SE32/03-011145-01
SAGEM SA document. Reproduction and disclosure forbidden.
65
E
S
When using the Deister contacless card reader, COM1 parameters
should be:
Setting up COM2 port
To activate this port, press the
CONFIG
key to access the
configuration files. Press the
NEXT
key until the file menu shows
"/cfg/Maccess". Press the
EDIT
key, and select the RS232 section.
The values are:
Baudrate
Databits
Stopbits
Parity
Flow ctrl
3 (9600)
8
1
0
0
Parameters
Value
Comment
Send
0 (default value)
The RS232 output is not
activated.
1
The RS232 output is acti-
vated.
Format
0 (default value)
The ID is sent in ASCII for-
mat.
1
The ID is sent in Hexa for-
mat.
2
The ID is sent is BCD
(1)
format.
(1)
BCD: Binary Code Decimal
PREV
NEXT
EDIT
EXIT
FILE: cfg/Maccess
SECTION:
COM2